Recent content by ptarka

  1. P

    Tiger loop is empty

    Hi guys, I have an oil fired boiler with a tiger loop. The pipe run is about 8 meters and the burner is about 4 feet above the bottom of the oil tank. I have lived here for 2.5 years and the boiler and tiger loop are 11 years old. Ever since I moved in, if the oil level in the tank gets down...
  2. P

    Heating/ timer problem

    Thanks John, but ive already been there. My timer is discontinued so they only have the user guide on offer ( does not show how to dismantle to reach connections) At the moment ( since the swift tap ) everything works perfect, although I know there is a loose terminal connection in the timer...
  3. P

    Heating/ timer problem

    I am neither. I only just recently moved in, hence the want to sort the heating system! I have also said above that I am getting one. Also to consider getting a new timer without even looking inside this one first could well be throwing money away. Besides, I would still need to get this one...
  4. P

    Heating/ timer problem

    Anybody please??
  5. P

    Heating/ timer problem

    Thanks John, A room stat is definately on the shopping list but I need to get the system working well first. The first job is to get the timer apart to check the connecteions. If they are sound, then i need to look for dry joints on the PCB. Question is, is anyone familiar with this...
  6. P

    Heating/ timer problem

    Hi huys, been a little while but i finally found time to have a fiddle! My goal was to find which wire was the CH on from the timer. After working out which one it is i put my tester on it and turned on the heating. Tester was reading nothing so I assumed the timer is at fault. I had already...
  7. P

    Heating/ timer problem

    HORSTMANN H27 CHANNEL PLUS XL PROGRAMMER HONEYWELL F5 9918 3 port valve Wall star oil fired boiler No room stat, just TRV's Feed expansion setup Hope that helps
  8. P

    Heating/ timer problem

    Thanks for your reply. My system doents have a room stat, just TRV's. When you say a faulty micro switch (dirty/burnt contacts), do you mean within the 3 port valve head? Also, will the pump not run unitl the valve has completed its operation? I moved the lever on the valve (honeywell)...
  9. P

    Heating/ timer problem

    Hi guys, I have 2 problems with my central heating and wondered if anyone can help please? I have an oil fired boiler with FE setup. 1: When ONLY the hot water is on, the radiators get quite warm. Im assuming the 3 port valve isnt completly closing off the heating side. Does this mean the...