    Driveway Floodlight Replacement - Standalone PIR and Additional Downlights

    Thanks for your suggestions Eric. I've considered smart bulbs/plugs/sockets as I've got a comprehensive smart system and routines through alexa inside the house. For the driveway though, I wanted to keep it as simple as motion detected = lights on for 1 minute or so. I don't plan on having them...
  2. R Stringer

    Driveway Floodlight Replacement - Standalone PIR and Additional Downlights

    Good Afternoon All, My existing PIR floodlight has failed and I am looking to replace it with some additional upgrades The PIR on the floodlight didn't do a great job at picking up motion and I could often walk right up to it before it would detect movement. It wouldn't detect when I drove my...
  3. R Stringer

    Nest Thermostat Gen 3 - Dual Zone Install

    Just posting back to report that I followed your advice and successfully installed both thermostats working perfectly! So big thanks for your help mate. The hardest part was accessing the wiring centre which I assume has been incorrectly placed directly behind the zone valves. Squeezing the...
  4. R Stringer

    Nest Thermostat Gen 3 - Dual Zone Install

    I was planning to redirect the brown and grey wires from the old stats directly into T1 and T2, leaving the blacks unused. Is that incorrect?
  5. R Stringer

    Nest Thermostat Gen 3 - Dual Zone Install

    Thank you for taking the time to write such a detailed response Stem. I’m just looking to clarify, Are you saying that rather than adding two new lengths of cable from the blue and grey connections from the zone valves to the Heatlink L & N, I should take the grey and brown from the TPOne...
  6. R Stringer

    Nest Thermostat Gen 3 - Dual Zone Install

    Hi all, I’ve read many threads on many forums trying to piece together how my system should be wired but I’m looking for guidance from those more knowledgeable than I. I have a new build with a Logic ESP1 35 Combi Boiler working with 2 Danfoss TPOne-M thermostats on a 2 zone valve system -...
  7. R Stringer

    Wiring a PIR floodlight

    Thanks fellas. I’ll do that so it’ll look like this;
  8. R Stringer

    Wiring a PIR floodlight

    Thanks Terry - really appreciate the help. currently, no, the sockets are only used for a lawnmower. Would there be any difference going from the existing FCU into another FCU rather than the socket? Reason being it’s much closer to the security light and would save me buying more cable.
  9. R Stringer

    Wiring a PIR floodlight

    Yeah just one double socket. The OCP is a 16a MCB at the consumer unit cable from house to FCU I believe is 2.5mm T&E (apologies garage is not connected to go check) cable from FCU to double socket is 2.5mm T&E. They also used 2.5mm T&E from FCU to light.
  10. R Stringer

    Wiring a PIR floodlight

    Hi Terry, thanks for your reply. Yes the garage is RCD protected at the consumer unit in the house. The existing light is fed and switched on/off by the switched FCU with a 3amp fuse. The socket is fed from the supply side of the FCU and not fused. I can’t go from the load side of the FCU as...
  11. R Stringer

    Wiring a PIR floodlight

    Hi all, I’m looking for some advice regarding the best way to wire a 54W PIR floodlight to my garage. I have used the floodlights pre installed 1m of cable to enter the garage and added 1.0mm T&E cable via a choc bloc inside an in-line connector box. The garage is powered from a radial coming...