Recent content by Readytolearn

  1. R

    Bifold doors

    There’s a wooden joist above the opening , I’ve measured the height on both sides and there’s 36 mm difference from one side to the other . Seems a big gap .
  2. R

    Bifold doors

    Tried convincing me that’s the way it should be . There now looking for work somewhere else…I’ve told them to pack there stuff up…… Apparently it’s fine to screw doors up-to roof joists.
  3. R

    Bifold doors

    My argument as well, I know nothing about building… so I guess it was going to be a quick in out make a quick buck never to be seen again job. So when doors start to not open properly , cracks in plaster appear etc etc . Hey Mr builder . Sorry not available
  4. R

    Bifold doors

    Hi , thanks for the replies ,,,,, I guess somebody is trying to cut corners :(:(:(:(.
  5. R

    Bifold doors

    Hi, just wandering of its ever an option to install bifold doors without an rsj. Just screwed into roof joists. Is this a poor idea. Thanks
  6. R

    Outside compression tap leaking

    Hi , thanks for replying this is the tap through the hand sized hole . A would have to cut away some of the unit to gain access. Thanks
  7. R

    Outside compression tap leaking

    Hi, the outside tap has started leaking and is tucked behind one of the base units on the kitchen. I can only see it through a hand size hole from where we isolate the water. It looks like one of those wickes outside tap kits that screws into the main water pipe . The tap itself is leaking. If...
  8. R

    Heating and water only working seperate

    When using the timer on pre set starts like morning and night both heating and hot water both come on fine together , the problem starts when we slide both on at irregular times , sliding one on will work but both only the first one which starts up will work,, hope that makes sense ,thanks for...
  9. R

    Siemans 2 port valve

    Spoke to a neighbour , who said it could be the controller that's faulty not the valve as the syncron motor is turning , would this be the fault ?
  10. R

    Siemans 2 port valve

    Hello , the central heating has stopped working ,I think it has something to do with the 2 port valve , the hot water side still works fine,and I can see the syncron motor on the central heating side turn but this does not switch the pump on or the boiler which is an old back boiler . Thanks for...
  11. R

    washing machine not switching of after cycle

    Has any body any ideas. I've pulled washer out and removed lid so can get to all parts
  12. R

    washing machine not switching of after cycle

    hello ,our washer is working fine until it gets to the end of its cycle and spins to drain the water off which it does ,the only problem is as soon as it starts to turn off it restarts the spin cycle and go,s through the spin again,recently i cleaned the pump filter as there was a hair grip...
  13. R

    HONDA IZY HARD TO START

    Ok Will check all linkages and cables. It starts first pull now no hassle and runs smooth.been a good mower for years and never really had to touch it.
  14. R

    HONDA IZY HARD TO START

    How do i slow the revs down
  15. R

    HONDA IZY HARD TO START

    Just had a look and your right the choke flap isn't moving . I couldn't work out why at first but its all been an own goal .when Ive stripped carburetor Ive put linkage in wrong hole . Its all back together now and started first pull just the revs seen very high. Thanks again .sometimes you Cant...
Back