Recent content by Rulland

  1. R

    Texecom Smartcom flashing blue cloud led

    Com 2 requires setting as 'Com IP Module'.
  2. R

    Texecom Premier Elite Configuration

    Hmm!, incorrect sir. A Guard access zone will only start the part set entry procedure if the ENTRY/EXIT 2 attribute is enabled. Likewise, a GUARD zone will also start the part entry procedure if the ENTRY/EXIT 2 attribute is enabled. EG, normal route in is via the kitchen door, keypad is by the...
  3. R

    Texecom Premier Elite Configuration

    Guard access, as they look at the keypad area, so require guard access when entering from the front door. Also be aware there is a period-3 to 4 minutes, before a wireless PIR 'wakes up', so if you're part setting, give that time before coming down and triggering them to start the entry timer...
  4. R

    Texecom Premier Elite Configuration

    In attributes 1 for the PIR's that you want to start the entry timer when part set, put option 7, ENTRY/EXIT 2, on.
  5. R

    Texecom Smartcom flashing blue cloud led

    Register yourself, and then add the site onto your cloud account.
  6. R

    Texecom Smartcom flashing blue cloud led

    As Secureiam, just reverse all programming for the Smartcom, and then start from scratch, that should auto populate ARC settings etc etc as required.
  7. R

    Texecom Smartcom flashing blue cloud led

    Primary number should be 127.0.0.251
  8. R

    Texecom Smartcom flashing blue cloud led

    Check that the IP address in Digi Options, Arc 1 is set to 127.0.0.251
  9. R

    Strobe light doesn't work as expected but siren does on Texecom Premier Elite 64w

    Those two 'pulsing' lights are known as comfort LED's, to show that the external sounder is 'live'. The strobe part is much more pronounced and brighter, it should flash approximately once a second when testing.
  10. R

    REPLACING A PIR

    What is your reason for thinking you may have to change a detector?.
  11. R

    Accenta 8 Replacement - Pyronix 76 or Orisec

    You only have six zones, one keypad and one external sounder, and an internal speaker?. There are a few members here that can be of assistance, me included, if you go down the DIY route. Although my knowledge on Orisec and Pyronix is limited, I've fitted literally 1000's of Tex stuff. What you...
  12. R

    Accenta 8 Replacement - Pyronix 76 or Orisec

    Just a quick follow on from Secureiam's superbly explained reply. If deciding on Texecom, I'd recommend using the 48 panel, this has the option for 4 wire zone connections, meaning instead of a global tamper-where all the the tampers are connected in series-each zone has its own tamper...
  13. R

    Scantronic 9448ES - Keypads unresponsive

    First thing to do is change the battery, if a fuse had blown you'd have nothing at your keypad, dim or otherwise. 20mm fuses.
  14. R

    Scantronic 9448ES - Keypads unresponsive

    Panel battery possibly got severely discharged during the power cut, and when power came back on the system voltage is now to low due to trying to charge a faulty battery?. Is the system regularly serviced?, do you know when the battery was last replaced?. Hazarding guesses from the limited...
  15. R

    Texecom Flasher Interface CDH-0001

    For app use, Texecom connect...requires v4 minimum, apart from that.....
Back
Top