Recent content by S0LUTI0NZ

  1. S0LUTI0NZ

    underfloor heating

    4800w divide by 240v = 20amp load 6242Y 2.5 T&E cable
  2. S0LUTI0NZ

    GARDEN LIGHTING ADVICE

    Alternative approach which could also assist with gardening / DIY / car cleaning etc, would be to have your electrician fit an outside socket.
  3. S0LUTI0NZ

    outside socket

    If ring main covered by RCD, then no need for additional breaker. If location of outside socket is reasonably protected from elements etc., the IP44 will suffice however, if in doubt, go for IP56. [removed]
  4. S0LUTI0NZ

    Air in one radiator

    It would appear that you have a minor leak somewhere in your system and the air is collecting in the radiator highest up in your system. If you can't locate it, one way to get rid of the air would be to replace the standard bleed valve, with an automatic one which operates onlt when the internal...