    12v SLA Battery keeps charging over 15v?

    The batteries are charging in the scooter. Both batteries are the same make, type etc. The charger is 24v.
  2. S

    12v SLA Battery keeps charging over 15v?

    The battery is constantly being charged at 15.5v, this is not normal. It is being overcharged which is not good for the life of the battery and can be dangerous. Please note this is not a car battery nor a car's charging system. I'm trying to find the reason why it is being overcharged, as the...
  3. S

    12v SLA Battery keeps charging over 15v?

    No the original batteries were not holding a charge. The terminals are the correct way round, I mean the position of the battery when seated in the scooter. I have the original 24v chargers that came with the scooters when bought new. Basically one battery is charging at over 15v, this will...
  4. S

    12v SLA Battery keeps charging over 15v?

    I picked up a couple of second hand electric razor scooters with charging issues. The batteries would only charge for a few minutes then the fully charged light would come on the charger. I figured the batteries in the scooter ( 2 x 12v SLA) were needing replaced. I replaced the 2 batteries in...
  5. S

    Can somone help with air in central heating problem cheers

    There is a much smaller tank in the loft but the water looks quite stagnant, could it be blocked or something? I havent tried no will give it a go thanks
  6. S

    Can somone help with air in central heating problem cheers

    I don't know where the air was coming from the last time. The pump was noisy and I suspected it was on its last legs but I wasn't convinced it was the pump that was causing the air in the system. The engineer said the pump was needing to be replaced and he said he could hear the air in the...
  7. S

    Can somone help with air in central heating problem cheers

    does anyone have any ideas what the problem could be? thanks in advance
  8. S

    Can somone help with air in central heating problem cheers

    I switched the heating on this morning and it was running quiet, but that's normal, it runs quiet when its cold. Its only when it starts to get warm the whistling sound is there. Sure enough as it slowly starts to build temperature this morning, the whistling noise/air is creeping in. I...
  9. S

    Can somone help with air in central heating problem cheers

    I'll try adjusting the valve but there are no numbers on it? The pump is a Grundfos UPS2 15-50/60, it's set to speed number 2 (the middle one)
  10. Untitled

    Untitled

  11. Untitled

    Untitled

  12. S

    Can somone help with air in central heating problem cheers

    Yeah the middle pic is displaying correctly. The original pump was in the same position too.
  13. Untitled

    Untitled

  14. Untitled

    Untitled