Hi....thanks for your answers....I have a two gang / 2 way lighting switch with quite short supply cables - 1.5mm T & E and there is not much room for any JB....the wires are quite short and it would be easier if the supply feed (L & N ) was to be taken into a connector block inside the switch...
Hi guys....my question is.....can both Line & Neutral be put into a connector block within a deep lighting switch box ?....would be easier due to short cables giving insufficient length for JB behind....ta for answers...
Thanks Davy.....yes, he has on old house on 3 levels and has opened up into the loft area as a bedroom / study.......nice....Having said that....trying to ensure he follows advice can be difficult........typical Professor with little common sense !!!
ATB and thanks....
Davy....thanks.....I agree with your sentiments re the first line but why would the early provision of cable preparation be classed as ridiculous comments - his ring main was installed some eighteen months ago with the runs looped to intended s/o boxes....and so prior to LBA adjudication....but...
Thanks Guys....
the work my mate wants to do is an attic extension in an old three level house....I believe he has notified the LBA but he is just pushing on with the wiring and replacing floorboards etc without having visual inspection...can this be done ?
can he claim that the old...
Hi guys....
just a quick one.....my mate has about 1 trillion mtrs of various sized old red / blk cables - flat T & E.....he has asked me can he use them on new installations if he sleeves them with appropriate colours....any advice please as he spent a fortune on these cables a couple of...
Hi Guys....take a look at this link....I thought I had seen most things.....
http://www.liveleak.com/view?i=988_1182656655
Regards to all.........sausage1
Hi Guys
3 Core 3 phase SWA 2.5mm - BK/BN/GY - already owned for connecting adjacent Garage for lights + 1 off s/o via Garage Unit fed directly from CU on own CCT ........it will be notified...
Can Sleeving be used to Colour the Cores to correct colouring ?...or will the sparks have to...
Hi Wes...
I think your friend is getting confused with parts of a circuit drop like feeding thru conduit run to a switch / sckts etc....
Drilling the joists to allow cable routing is ok (subject to build compliance on hole size / position etc) - see link but clipping is ok, but perhaps...
Yeh........those guys have to wear special overall suits of copper due to the PD across the wire..........can be hundreds of volts over a metre....mmm....rather them than me !!
Hi guys....
my mate is doing his house up....extending into the loft and fitting it out as a Study / Bedroom....it is quite old with lovely old beams and cross pieces, purloins etc...he has asked if it is possible to surface mount the flat T&E lighting cables in order to conceal as much as...
hi _davy_owen_88
Thanks....yes....my mate has notified the Local Building Authority...
Re the false wall insulation....and the DP upgrade on the RCBO, would this be due to the 10mm cable being classed as enclosed ?
Much Obliged....for this and previous answers... :roll: