Recent content by ScottieN

  1. S

    Ariston Microgenus II 24 - No hot water

    Well only if you take the chance on an "Engineer". The chap that my sister called was the plumber that fitted the boiler 10 years ago and has serviced it each year since. £150 for the part he recommended plus the attendance fee plus the fact that he wasn't interested in actually fitting...
  2. S

    Ariston Microgenus II 24 - No hot water

    So just in case it's useful to anyone else, The DHW flow sensor switches the pink and white wires. Bridging the pink and white wires together on the board with a small wire, I was able to fire up the hot water. So not the diverter valve nor the board have a problem. Ordered a new flow...
  3. S

    Ariston Microgenus II 24 - No hot water

    Madrab No error codes. Display just shows on when in summer mode and the heating temp when in winter mode. All normal as far as I can tell. Dan Not sure really. Think I was just hoping that the rather gammy looking DHW flow sensor was the easy option. If I could eliminate this I could...
  4. S

    Ariston Microgenus II 24 - No hot water

    Hello, My first post and sorry it's quite long but.... I have been scanning the web to try to find the answer to the no hot water problem with my sister's boiler. These forums seem to have a lot of answers but most relate to a diverter valve problem, which I'm not convinced is where I...
Back