Recent content by screamer

  1. S

    Clicking stack

    Above my kitchen ceiling i thought i heard a dripping sound. I stayed in the house for 20 years, just before selling it i thought i needed to investigate it, turned out the bath waste went into a soil pipe in the ceiling space, it was the hot water from the bath/basin expanding the soil pipe...
  2. S

    Mira sport 9.8 leaking when off

    I had a Mira sport 10.8kw shower that started dripping all the time, got in touch with Mira tech support who said it was the flow valve, they gave me the part number and link to their site to buy it.
  3. S

    TRV4 Auto Balancing valves

    Yeah, but it does need balancing as furthest rad away doesn't heat up as much.
  4. S

    TRV4 Auto Balancing valves

    Got Normal TRV4 radiator valves but wondering if the auto balancing are worth a change to? I've not got system balanced Or better just keeping the normal TRV4 and balance the system? Also, do they fit onto the body of the TRV4 body or is it a complete valve change?
  5. S

    What type of TRV is this, and what electronic or smart replacement can I use?

    they look like to Danfoss heads? Wiser heads may fit going by this with the adapter
  6. S

    Help: How to replace the small chrome towel rail in a cold damp bathroom

    remove the plasterboard, insulate with PIR insulation but you have to keep 50mm of free air space between the top of the PIR insulation and the roof/tile battens/felt. Then put a vapour barrier (a thin polythene sheet) all over the ceiling then plasterboard (you can also get insulated...
  7. S

    Radiator Issue

    Grub screw as mentioned but i think they may be just push on and tighten the grub screw. I had them in my old house but can't remember now.
  8. S

    Danfoss RET2001M no display when not in use

    @stem Cable fitted and working as it should be, cheers (y)
  9. S

    Magnetic Filter Install

    The TF1 Omega 62249 with valves has a larger cut out size https://www.plumb2u.com/PBSCProduct.asp?ItmID=32399705&AccID
  10. S

    Danfoss RET2001M no display when not in use

    I have been looking at them, mainly Google Nest I did ask WB if their boilers supported opentherm but they said they didn't. (not that i know much about opentherm) My boiler is a 37CDi (13 years old)
  11. S

    Danfoss RET2001M no display when not in use

    Thanks for the detailed info. As you say, it needs a permanent live between the stat and programmer which there isn't one there, I'd need to run another cable to add this?
  12. S

    Danfoss RET2001M no display when not in use

    this is the back of the programmer
  13. S

    Danfoss RET2001M no display when not in use

    I have the above room stat but it doesn't show anything on the digital screen until the programmer tells the boiler to turn on. Is this meant to have a live feed for display power all the time? It's a Drayton L711 1 channel programmer is it makes any difference