    honeywell v4073a HELP PLEASE

    wiring all ok the back feed is there when its dis-connected with only the grey CH off cable connected and Neutral / Earth the CH off should be at 240v in this state 0v-45v on white wich is call for heat and o-45v on orange which is call to boiler. if i take the motor head off the valve it all...
  2. sfechalky

    honeywell v4073a HELP PLEASE

    still seems quite a high voltage 150v but how can i rectify this as all that was wrong with the system before was the valve was stuck between HW and CH so i freed it up with some pliers but after 3 months it happened again so i replaced it with this Honeywell one. the back feed voltage is enough...
  3. sfechalky

    CCTV recordings

    We used to look after a few jewlers but you could go for Bears that have been poked with sticks by angry dwarfs.
  4. sfechalky

    Is my new DeWalt drill normal?!??

    Have had my 18v dewalts for 8 years use them most days and there still as good as they were when i bought them. A friend of mine bought a makita kit and the triggers on the drills keep going.
  5. sfechalky

    I find hitting things normaly fixes them. If that dosent work shout at them and hit them harder.

    I find hitting things normaly fixes them. If that dosent work shout at them and hit them harder.
  6. sfechalky

    CCTV recordings

    We used to put an old timelapse vcr and monitor on the monitor output of the dvr in a nother location in the house. then all you need to do is give them the tape and all your dvr footage is still safe in another room.
  7. sfechalky

    honeywell v4073a HELP PLEASE

    Because with the valve connected to the wiring center and the white and orange cables removed from the terminals i am getting a voltage of 150v on the orange and the white. if i connect a switch to the boiler and manualy switch 240 to it it works fine when 240 removed the boiler shuts down as it...
  8. sfechalky

    Noise bars on CCTV screens

    When i change power adaptors over, the sevarity of the noise bars changes over to the other camera as well the noise moves with the psu (faulty psu) as mints73 said. Hi mate change the 12v power supply for a new one on the camera that is the worst or just remove the psu on the camera that...
  9. sfechalky

    CCTV

    Hi mate it all depends how much you want to spend i have just installed a system using conventional camera's (micky domes)but they are then encoded to ethernet and then sent via a ethernet wireless point to point network to the decoders and then on to DVR 15miles away.throughput on point to...
  10. sfechalky

    honeywell v4073a HELP PLEASE

    Hi guys have a honeywell v4073a valve this is now the third one thats been installed on my system in as many weeks. the problem is that the CH is still calling for heat when everything is off. Even with the valve wired with just the grey,blue,green, cables connected there is still 150v back...