Recent content by skilly

  1. S

    Terracing The Garden

    I intend to finish the garden this summer and have decided to terrace it due to a 6ft high slope at the back end of it. I was going to build a couple of walls until I saw Deefadog's project using 4" half-round logs.....now I'm going to copy...
  2. S

    Post Borers

    I have to plant a lot of posts to support my new deck and was going to hire a post borer for the job. Question is can a manual borer deal with heavy thick clay soil or should I bite the bullet and get a powered version? Cheers
  3. S

    Unusual Decking Question...

    Back again!!! Went to get prices for the timber and completely baffled myself....it ain't difficult. What timber should I be ordering?? Treated --- yeah. Strength graded??? Regularised??? What is the differences between these types and what should I be getting? Many...
  4. S

    Unusual Decking Question...

    Cheers guys.. One other question....am I better nailing or screwing the joists to the frame?
  5. S

    Unusual Decking Question...

    I am about to start building my first deck and have was wondering how much load can they carry? I intend to build a 2 tier construction (one on the ground 12'x16' with a 4"x2" frame throughout and the other 12'x15' approx 24" off the ground with a 6"x2" frame and 4"x2" joists). I will be...
  6. S

    Ring Main layout

    Thanks for the replies guys. I hadn't heard of the kitchen being on it's own ring before...(I don't work on domestic wiring) and since I've found a few 'quirks' in my mum's new house I thought I'd ask. Her house was supposed to have been completely rewired recently but only the...
  7. S

    Ring Main layout

    Can someone please confirm the 'correct' layout of connecting sockets in a two storey house? I always thought that they should be split into upstairs and downstairs, but I have been reading that the kitchen should be on it's own separate ring no matter which floor it is on. My own...
  8. S

    Lighting circuit question

    Thanks for the quick responses. The existing fitting is a normal 240v pendant fitting, in the kitchen. But I have also opened a couple of other roses in other rooms (not the bathroom though) and found the same yellow switch wire. I can't ever remember seeing a yellow wire in a domestic...
  9. S

    Lighting circuit question

    My parents are moving house shortly and when I went to fit a new light fitting I found the following in the ceiling rose: 2 Black wires connected to Neutral of the lampholder. 1 YELLOW(?) wire connected to the live of the lampholder. 1 Green/Yellow earth cable. The light switch has 2...
  10. S

    Is my lighting circuit legal??

    Newbie here folks so please be gentle with me... I have just moved into a new build house and have replaced a couple of light switches with dimmers and a couple of ceiling roses with new fittings. My 'problem' is this.... I know that lights are generally wired using the Loop-in...
Back