Recent content by spike66k

  1. S

    F26 after replacing valve, help please!

    Thanks guys. I have turned the boiler down a smidge and left the power off for an hour. There has been no f code in the last 8 hours! Keep your fingers crossed, and many thanks
  2. S

    F26 after replacing valve, help please!

    I rebooted the boiler.... it seems to run fine for a couple of hours, and then gives the f26 code
  3. S

    F26 after replacing valve, help please!

    I get both. I have a new motorised valve that I could fit if needed.... but the old one still seemed ok.
  4. S

    F26 after replacing valve, help please!

    I can do, but I would have liked to hear experience from someone on here! I expect my plumber will not no the cause of the issue.... and will guess at trapped air, or just keep charging me to replace thermistors, and other bits. I’m not in very good health, and hoped someone on here might give...
  5. S

    F26 after replacing valve, help please!

    As it was at the top of the system, there was very little water- so the plumber did not drain the system down.
  6. S

    F26 after replacing valve, help please!

    Two way port valve that is underneath a motorised head. The valve stuck open a bit and constantly called for hot water, so it was swapped out. (Copper valve? I hope this describes it properly !! Thanks
  7. S

    F26 after replacing valve, help please!

    Sorry to trouble you all. Replaced the copper valve under the motorised head yesterday - but the Glow-Worm hxi 38 boiler now gives an F26 code after a couple of hours. Bled all the rads and no air in them. the code book mentions return temperature thermistor- but it seems very coincidental that...
  8. S

    Neff hob, only 3 of 6 igniters working? Help!

    Thank you ! That makes sense to me. I really appreciate your reply Spike
  9. S

    Neff hob, only 3 of 6 igniters working? Help!

    Hi all. Smelt an unusual smell under hob (not gas smell) . Tried hob and only 3 burners of the 6 spark ! (All on one side) Any ideas please folks???? I've cleaned everything but still only get spark on first 3 burners. It's neff, -about 8 years old. Look forward to hearing from someone please! Spike
  10. S

    Ticking from fuse box!

    They are led lamps
  11. S

    Ticking from fuse box!

    Thanks for the advice. Can the dimmer switch be making the fuse box tick?
  12. S

    Ticking from fuse box!

    It just does it for the three wall lights that are wired together. Can turn on everything else, but no ticking in the fuse box, until I turn on wall lights. They are connected to a two gang two way switch in one room (dimmer which doesn't work well) and a single switch at the other end. The...
  13. S

    Ticking from fuse box!

    He hasn't finished the job yet to leave a cert. I've used him on many jobs before. Any idea of the ticking noise in the fuse box please?
  14. S

    Ticking from fuse box!

    Hi all. I have ticking coming from one of the trip switches in my fuse box ! I have just finished an extension where the sparky "tagged on" a few led lights to the upstairs lighting circuit. By a process of elimination (turning everything on and off) I have isolated the ticking in the fuse trip...
Back
Top