Recent content by Squares

  1. S

    Lintel Above Patio Door

    Hi there, thanks for the response. Regarding your question; "Why did you callout the first company again, knowing that they had made a pig's ear of the first install?" We didn't know until now they made a pigs ear of it. In 2003 they installed the door for the prev owners and in 2008 we were...
  2. S

    Lintel Above Patio Door

    Hi all I wasn't sure where to post this under doors/windows or in this section but here goes....... We bought our property in 2005, it's a 1969 3 bed semi. Timber framed internal walls, brick skin external wall with cavity then block on the inside of the external wall. In 2003...
  3. S

    Vokera Compact 25HE DPS (Air Pressure Switch) Bouncing....

    That's ok. BTW how do you know I'm not gas registered? Having a card/cert to say your certified doesn't mean you are competent, my experience from dealing with heating engineers....
  4. S

    Vokera Compact 25HE DPS (Air Pressure Switch) Bouncing....

    Although I am thinking of getting a set of new venturi and pipes (I think they are around £15+vat for a kit) as I read somewhere even the smallest amount of crud could make the DPS play up. Also I read if the main heat exchanger plates are dirty this could cause reduced air flow and maybe the...
  5. S

    Vokera Compact 25HE DPS (Air Pressure Switch) Bouncing....

    Hi Terrywookfit Took the pipes off the venturi, un-screwed them from the fan and looked at them close up, they were not blocked for what I could see. Poked something through them while in my hand too...
  6. S

    Vokera Compact 25HE DPS (Air Pressure Switch) Bouncing....

    Hi I have a Vokera Compact 25HE with DPS bouncing. Basically with any demand the fan runs, pump runs, all sensors ok and relevant switches closed, DPS closes, boiler fires. After about 20secs flame goes off, when I check the DPS it's open circuit, wait about 45s-1min, DPS closes and boiler...