Recent content by Squealer

  1. S

    Baxi Solo 3PF - blowing fuse

    Hi guys, Thanks for the pointers. I isolated the fan and that stopped the fuse blowing. I checked the harness which was ok and then pulled the fan assembly out and it looks obvious that's where the problem is - one of the windings is burnt to bits!! Thanks again for the prompt help. Paul.
  2. S

    Baxi Solo 3PF - blowing fuse

    Hi all. I wonder if anyone can offer some help in diagnosing a problem with my boiler? It’s a Baxi Solo 3 PF and keeps blowing the 3A supply fuse when a call for heat is made. Initially I thought it might be a problem with the wiring, pump or valves. However, I’ve tested the pump and that...
Back