Recent content by staffs

  1. S

    Problems with Baxi 105e combi despite new expansion vessel

    We have had this before and it drove us nuts. Howeber turned out to be the secondary heat exchanger at the top of the boiler which was leaking and water was going down the condense line so therefore no visible leaks.
  2. S

    Bambergaspipe a "Gas Engineer"...lets have a vote

    met a Plumber from Yorkshire whilst on hols and his business card quotes.. "Why sleep with a drip when you can get me ? " How corny is that then ? How Yorkshire Too ?
  3. S

    3.15A Fuse blows on control board (Ravenheat RSF 820/20)

    fan speed resistor shorting out to the casing is a common fault on this model. undo the fixing screws and remove it from the casing and then see if the fuse still blows. It is locateed at the back of the casing on the rhs about half way up .
  4. S

    Time served plumber

    TART !! We are one of the same breed gas4u ....you need to tell these infidels and uneducated that we are...." Heating Engineers "
  5. S

    God bless our Eastern European chums.

    Who ?? The Unregistered and ignorant who who work on Gas ??
  6. S

    quote is it expensive

    Dan.... nudge nudge wink wink !!!! :P :P eh got any other pics along those lines that might be of interest ????? :shock: :shock: Do you a swap of a dodgy oil tank installation getting quite familiar with a nearby LPG swimming pool boiler !! :roll:
  7. S

    quote is it expensive

    Dan !!! Stop it PLEEASSE I am getting a little too excited with those pics of That "Dirty Old little Vaillant" What a cheeky minx !!! TISSUE !!!!!! :shock: :shock: :shock: :shock: :shock: :shock: :shock: OK and point taken. However i think vaillant did actually admit that...
  8. S

    fittings

    NOW I AM SCARED !!! VERY SCARED Just glad the question was asked in the first place instead of just assuming.
  9. S

    God bless our Eastern European chums.

    ALWAYS cover your own back just in case.. You are the responsible person and if you are the last one there then you are even more accountable. You probably already know but RIDDORS can be completed and submitted online It is up to those who DO comply to start doing something and let that...
  10. S

    God bless our Eastern European chums.

    So why arent CORGI and HSE doing something about such situations. If it was you or me then they would be crawling all over us . Wot no RIDDOR ..... isnt that a town in the old eastern bloc?
  11. S

    quote is it expensive

    Vaillant IMO: They are generally of a god build quality ..even now in the very competitive market. And their condensing boilers are fairly well tried and tested as there are quite anumber of the early Ecomax condensing models still around and working reliably. I know that that all...
  12. S

    Recommendation for Heating Oil Tank

    I presume that you are looking to fit an oil tanl with a storage not more than 2500 litres that is supply a single domestic dwelling only ? I am an OFTEC installer and get to see some horrendous oil tank installations that do not comply with the regs.just because the builder or installing...
  13. S

    IDEAL Boilers

    There are loads of these that were fitted on The Warmfront Grant works and yes thay are a load of rubbish IMO. Very expensive spares although now one pcb does all models and is interchangeable by fitting the jumpers to suit the model. the spares for these have actually reduced if you look...
  14. S

    old plumbing

    Its Plumbing !!!!! Its not quite as simple and easy as the TV programmes have you believe. :roll: :roll: The Glue is for sovent welding the plastic together.. If he is having a bit of trouble then maybe hes sniffing the glue fumes too much ? :shock: :shock: :shock: :shock...
  15. S

    Ideal isar m30100 problems!

    Check Pump first as previous. If the boiler opertes for a short while and the pressure increases not too quickly and the pump IS working then it might be an idea to isolate and drain the boiler and check the expansion vessel charge pressure. This will need to be done with the boiler drain...
Back