  1. T

    Ideal Mini C32 ignition problem

    He replaced the main PCB (Logic BI1475 116), not the ignition one. The only visible diagonstic light is the left most LED from the PCB that starts to flash rapidly when faulty. The user guide says this means either empty primary circuit, no primary circuit flow, no boiler ignition, excessive...
  2. T

    Ideal Mini C32 ignition problem

    Please can anyone help with an intermittent fault on Ideal Mini C32 combi boiler. When heating or hot water is requested, the boiler always 'runs' and you hear an ignition click, however it either; a) doesn't ignite and goes into fault mode b) initially ignites for a couple of minutes but...