  1. T

    Flat Roof ventilation

    I am insulating the walls and ceiling of a 6m x 3m breezeblock construction outbuilding for my father in law in Scotland that has a flat roof with previously no insulation and no soffits. The roof just covers the width if the walls with no overhang. It has double glazed windows and door. We...
  2. T

    Why do my 2 port motorised valves not last?

    what would you guys recommend as an alternate - either a 2 port valve or a design alternative? best tommy b.
  3. T

    Why do my 2 port motorised valves not last?

    1st valve lasted 7 or 8 years. Second one 2 years. Now another one on a different zone is opening but not sending a live switch signal out. Worked around it by sending the thermostat -on live signal to the boiler so dont need valve microswitchbto work. Any advice on getting valves to last...
  4. T

    Fit new mixer tap to a ceramic sink

    In support of elevonic. Bought a new mixer tap at IKEA. Pipe tails and the rest were exactly the same AND had flexible tap connectors so no need to move anything. The IKEA instructions DIDNT say you needed a box spanner. After an unpleasant WTF half an hour under the sink I found this...
  5. T

    isolation ball valve questions

    thanks kev. do you have any suggestions for something better? best tommyb
  6. T

    isolation ball valve questions

    hi I have a leaking isolation ball valve on a feed to a radiator. it has been in for a year with no problems but when I switched it off to change the radiator it leaked where the screw bit is. I am going to replace it but I wondered if the problem was maybe I had on the wrong way wrt water...
  7. T

    dpm under a hearth?

    thanks for the reply. is there no need for a dpm even if there is no dpm under the concrete slab and there will a dpm under the rest of the floor? cheers Tom
  8. T

    dpm under a hearth?

    Hi I am putting in a new hearth over an old concrete slab floor. The rest of the floor will be as follows (top down); flooring screed (with UFH) 75mm insulation 60mm DPM (1200 gauge visqueen) Old Concrete Slab When it comes to the hearth I know that I need to have a constructional...
  9. T

    underfloor heating - are these kits any good?

    I am not sure but most people say that underfloor heating works best when there is some sort of heat sink ie large mass to store the heat in the floor. so it works really well inside a concrete screed 75mm thick on top of insulation. The concrete heats up and stores the energy. Putting it...
  10. T

    dpm under insulation and screed

    the new building is tanked not yanked....sounds like I 'd had cowboy builders in.... best tommy b
  11. T

    dpm under insulation and screed

    hi I am fininshing off an extension joining onto an existing older building. The extension is yanked and the architect has spec'd Marley Dampseal for the dpm which will sit under 60mm of Kingspan and 75 mm of screed. A laminate wll be glued onto that. He has als psec'd marley dampseal ontop...
  12. T

    english roof in scotland

    Thanks for all the replies. I am using spanish new slate 14 x 8's. They seem to be going on easily enough Local authority are totally fine with the roof - it is not a requirement just a custom! You havent answered my main question though so I will try and rephrase? How do you repair...
  13. T

    english roof in scotland

    hi I have put up a cold unvented unsarked roof in scotland ie no boarding or sheeting but battens and counter battens over breathable membrane. The slaters who have looked at it up here all complain cos they say it is much harder roof to work on as they cant drive their supports for planks...
  14. T

    breathable roof membrane and valley gutters - what to do?

    yes they have give a warrant to the plans. mind you many people just assume there are sarking boards on it - ity is only when you look closely that you realise there aren't. I don't see why scottish building control would insist in it? tommy b.