Recent content by Tony59

  1. T

    Siemens iQ500 washing machine smooth and noisy anti clockwise. Uneven but silent clockwise.

    Thanks for the reply. I already disconnected the drain sump and cleaned it out. I also removed the heating element which allowed me to view the outside of the drum as I rotated it by hand. I could not see anything stuck to the drum. That makes me think that the object is stuck to the sides of...
  2. T

    Siemens iQ500 washing machine smooth and noisy anti clockwise. Uneven but silent clockwise.

    I have a Siemens iQ500. It operates UK, but when I turn the drum by hand the following happens: Clockwise: Silent, but resistance is felt around twice per revolution. Anti-clockwise: Spins more smoothly, but has a constant noise. I have removed the heating element to inspect the inside at the...
  3. T

    Old steel gas pipe removal in 1930's house

    In a bedroom of a 1930's house there is what I assume is an old capped town gas pipe. I assume that it was for a gas heater which would have been removed many years ago. The house has a modern natural gas supply to the kitchen only (ground floor), feeding the boiler and cooker. The bedroom is...
  4. T

    Bonding copper pipes joined by plastic isolation valve?

    Thanks for the clear answer. If the pipe to the outdoor tap was to go into the ground, would bonding be required then? I am just trying to understand the rules.
  5. T

    Bonding copper pipes joined by plastic isolation valve?

    I have an outdoor garden tap supplied from my kitchen mains supply. It has a gate valve as an isolator which does not work well. I wish to replace it with a plastic isolation valve (see photo). The piping from the isolation valve to the outdoor tap will be going vertically through the back wall...
  6. T

    Solar panel bracket lifting tiles

    Thanks for the replies. The installers have agreed to grind the back of the tiles. They said that it is not necessary, but they will do it to keep me happy.
  7. T

    Solar panel bracket lifting tiles

    The installers have advised that a maximum of a 5 mm gap is permitted according to MCS guidelines. It's a bit difficult to check the gaps. Also removing, grinding and replacing the tiles might weaken them.
  8. T

    Solar panel bracket lifting tiles

    I am having solar panels installed and noticed that the installer did not use an angle grinder to adjust the tiles and enable them to lie flat after installing brackets. He seemed to install the brackets very quickly. But they have not yet installed the cables for the panels, so perhaps I should...
  9. T

    Triton Enrich not working (ever)

    In the end, we replaced the shower with another Triton Enrich, without fixing any switches or anything else. The new one works fine. So perhaps the solenoid had failed on the previous one.
  10. T

    Occasional leak from roof tile vent

    Just for the record, I did 2 things to try to solve this: 1) I bought some foam filters intended for air vents to insert inside. These are intended to allow air flow through, but stop indirect rain etc. I think that it continued to leak after that, but I am not sure. 2) I attached a flexible...
  11. T

    AICO radiolink triggering neighbours alarms

    One of my neighbours did that and Aico recommended that we remove the radio devices from each house, then install them again, house by house, giving each house its own house code. So maybe that's what we will do. However I feel that we already installed them according to the instructions and...
  12. T

    AICO radiolink triggering neighbours alarms

    I have upgrade some smoke alarms in a house which now has 3 hardwired alarms and one wireless heat detector. All alarms are from the Aico range (Ei3016, Ei603RF). I have installed one radiolink module (Ei3000MRF) into one of the hardwired alarms. This allows the hardwired alarms to communicate...
  13. T

    Triton Enrich not working (ever)

    I seem to have exactly the same problem with a Triton Enrich. LED light goes on. The water supply is OK. But the shower won't operate. Did you ever find out what was wrong?
  14. T

    Smoke alarm wiring circuit

    I should have probably described the 1st option as 'radial'. In effect both options are types of 'Parallel' going by what is taught at school, since live and neutral are connected to each device. I doubt that text book 'Series' is ever used in real life. Anyway, what I want to know is should the...
  15. T

    Smoke alarm wiring circuit

    From the ceiling rose, the cable will be 2 core + earth. Series option: Between each alarm will be 3 core + earth. Junction box option: Between common junction box and alarms will be 3 core + earth. The 3rd core will be for hard wiring the signal. I have seen the series way being used before...