    trojanhawrs replied to the thread 15mm pipe bending help.
    It'd be tight, I'd recommend picking them up from screwfix and dry fitting, if it doesnt fit they're normally pretty good about taking...
  • T
    trojanhawrs replied to the thread 15mm pipe bending help.
    Corner valves are valves designed for pipework coming out of the wall, so the compression fitting points that way. Example Street elbows...
  • T
    trojanhawrs replied to the thread 15mm pipe bending help.
    You might get away with corner valves and street elbows. The smaller ones are about 30mm from valve centre to pipe entry
  • T
    trojanhawrs replied to the thread EV Charging..
    You need 2 cores for a CT clamp which will need to clip over one of the meter tails. So you could run 2 separate cables or you can use a...
  • T
    trojanhawrs replied to the thread Shed/aviary base.
    If you can get a hold of a couple pals I'd be tempted just to get a concrete lorry in, volumetric mixer. They'll make up what you need...
  • T
    trojanhawrs replied to the thread EV Charging..
    RCBO/RCD must be double pole and normally its recommended to fit a B40. Why wouldn't you just upgrade the tails? You could also just fit...
  • T
    trojanhawrs replied to the thread First fix rad pipes.
    Any reason you didn't just bring them out higher and use an angled valve?
  • T
    trojanhawrs replied to the thread Fitting toilet.
    You can also use an offset pan connector to bring it slightly closer to the wall if required
  • T
    trojanhawrs replied to the thread S plan wiring at boiler.
    The boiler manual is showing 1 core coming out of the boiler live (which is what should be feeding your wiring centre), and one going...
  • T
    trojanhawrs replied to the thread EV charger output voltage.??.
    I'm sure the EV needs to do some sort of handshake with the charger to bring in the contactor though, so it might not be that...
  • T
    Yep, the latter. The way you've drawn it the boiler would run constantly. You'd have to adjust boiler wiring to mess that up though!
  • T
    In a visual sense no, that is not how the black wire would be. It'd follow the diagram line. You shouldn't be touching that at the...
  • T
    Probably just haunched with nothing underneath it? I'd get 8 inch deep edgings, lift the black soldier course and dig out the old...
  • T
    That's reacting to the room temperature change (load compensation). Weather compensation is attempting to anticipate the demand before...