    glowworm flexicom 30 cx problem

    I was paying £21 a month but this covered all labour and parts ,and over the course of the year i had 1 x 3 way valve and 1 x heat exchanger fitted which would of cost god knows how much in parts and labour... If you can afford it change the boiler as they are nothing but trouble,i have just...
  2. T

    glowworm flexicom 30 cx problem

    Hi thats sounds like its your heat exchanger that has a leak for sure....im afraid they are expensive to change...i had mine covered on a insurance policy,i think you maybe looking at about £300 sorry to say. If im honest i had nothing but trouble with those boilers and only last week replaced...
  3. T

    glowworm flexicom 30 cx problem

    Are you sure that you dont have leak on your central heating pipework ,as if there is no water leaking under your boiler this would be the first thing to trace. The heat exchangers are made from cast alloy and rarely leak,mine was a rare case . Thanks Paul
  4. T

    glowworm flexicom 30 cx problem

    Hello,yes i sorted my boiler problem what it was there was a crack in the heat exchanger (cast alloy)and the water was disapearing down the pipe that is connected to the toilet sewer pipe,hence i never saw any water being lost. I solved the problem myself but what idid i isolated the heating...
  5. T

    glowworm flexicom 30 cx problem

    Thanks i will give it a try to see if thats the problem,if the pressure on my system is dropping as often as it is and there was a leak on the c/h would the water evapourate quickly hence i cannot find any leaks. Paul
  6. T

    glowworm flexicom 30 cx problem

    I have just took the front cover off the boiler and the red tank which is on the right hand side does have some water stains underneath it but it is not fresh ie dry ,could this be due to testing when building the boiler? What did you mean regarding putting the pressure upto 2.5 bar ...
  7. T

    glowworm flexicom 30 cx problem

    Thanks for the replies, when the boiler is in the F22 mode i refill it to 1.1 bar then over a period of about 24 hrs it will drop to the piont that the F22 mode appears again. Ihave placed a bag over the outlet pipe outside (pressure release valve) to see if i collect water in it. I have...
  8. T

    glowworm flexicom 30 cx problem

    I had the boiler fitted 18 months ago but over the course of the last few months it keeps going into fault mode F22 every 36 hours which is low water pressure. I have ripped the house to bits and traced all the pipes and found one suspect joint which i made good ,this increased the time scale...