Search results

  1. T

    DPF removal

    It is an mot failure to do anything but replace it with a working unit, you'll need the car remapped to delete it which is easy enough for most cars nowadays. You'll need to either force a hole through it from end to end the diameter of the exhaust pipework or cut it open and remove the...
  2. T

    WC into understairs pantry - nightmare

    Sorry but you've pretty much made it worse by including a flexi. Judging by the last picture you've way more fall on that pipe than you need, if you had less fall you'd be able to get all the pipework inline alot better and lose that offset joint aswell.
  3. T

    Relocating soil pipe and inspection chamber

    It's going to be seriously expensive especially given your not going to actually gain anything. There's no reason for there to be any issue with your sewer but if your after piece of mind ask your neighbour if either they have a cctv survey showing your sewer from when there sewer was moved or...
  4. T

    Do these compression need changing?

    Ok hopefully you can make sense of this, Remove the section of pipe circled in yellow and put to one side. Remove the blue filter, and both it's plastic fittings. Remove the copper loop to the right of the filter all the way to that Iso valve next to the blue line I've drawn. Get a 15mm...
  5. T

    Do these compression need changing?

    Is the direction of flow through the filter from left to right or the opposite way?
  6. T

    Do these compression need changing?

    Could you take a photo of the pipework to the left of that picture, the blue bit is basically installed in a loop so it's possible to tidy up the pipework further
  7. T

    Makita Radio

    No buttons stuck in?
  8. T

    Do these compression need changing?

    If there not leaking then no, I'd probably clean them up with a bit of emery cloth as then you'd know any future build up is a leak but it'll do no harm leaving them.
  9. T

    Sink Waste Query

    https://www.toolstation.com/washing-machine-plastic-valve-cap/p30766?store=null&utm_source=googleshopping&utm_medium=feed&utm_campaign=googleshoppingfeed&gad_source=1&gclid=Cj0KCQiAj9m7BhD1ARIsANsIIvAzPAPi9U38xkMmDm7HDg9beFhf4OvrKEXKQ2EmSq8aH-5FoAdQGbkaAgrREALw_wcB That would probably be my...
  10. T

    Sink Waste Query

    https://www.screwfix.com/p/mcalpine-s23u-multifit-blanking-plug-white-32mm/73053 I'm going to hazard a guess you want one of the above
  11. T

    Downstairs toilet options (looking for advice)

    You could get a socket bend which would allow the pipe to follow the line I've marked in orange, you could at least then box that bit in and have a chance of making it look reasonable once you repair the stair.
  12. T

    Would you pass theory driving test today? Try.

    I'm not suggesting I wouldn't stop and I have previously but given the theory test is supposed to be about the knowledge required to drive safely then whether you know anything about first aid or not is irrelevant
  13. T

    Would you pass theory driving test today? Try.

    Anything related to first aid, there's no requirement to stop if you come across an accident or to take any action if you do stop so why you should be forced to learn about any of it to pass a test to drive safely is beyond me.
  14. T

    Would you pass theory driving test today? Try.

    47 put of 50, still annoys me now as it did when I first did it for my test that your expected to know things that have zero relation to driving safely.
  15. T

    Firestop garage wall

    Is the dividing wall a cavity wall? To meet the fire requirement both the wall and ceiling will need to be either pink fireboard or a dual layer of 12.5mm plasterboard either option will then need plastering too. You'll need to speak to the building inspector re. the pipe openings, at one...
  16. T

    Remove a broken iron bolt (Ed.)

    Chip whatever that is left round the thread off and a decent pair of mole grips will probably get it out.
  17. T

    Temp oven supply

    I'm saying if the instructions say its needs a 32a supply then it can go on a circuit that's rated at 32a, especially as a temporary fit. I think the op has shown enough understanding so far to not have everything on that circuit running all at once.
  18. T

    Drilling above interior doorway?

    I wouldn't bet on there being a lintel and it not just being block work especially if there isn't anything sitting on it upstairs, they'd just use the door casing to hold the small amount of weight. Just use a standard masonry bit and drill into it with hammer switched off and you should be...
  19. T

    light switch wiring

    I think it should be, common setup stays the same, then the wires in L1 on the old switch will go in the 1 Way terminals on the new switch
  20. T

    Temp oven supply

    If the socket is on a ring final protected by a 32a mcb or rcbo then you could change the existing socket to a cooker connection unit and wire the oven to it
Back
Top