    How long should a 12v Car Battey last?

    I've a length of 2.5mm2 coax cable with croc clamps and have started numerous cars at the airport but allways run the engine for 10 minutes or so before attempting to crank the other engine, seems to work fine. Of course the 2.5mm2 limits the amount of donar amps, better for my car but still...
  2. J

    Cold radiator

    Is it a sealed or open vented system.? Is it a gas or oil fired boiler? Where is the boiler located? If oil fired where is the circ pump located.? What make/model/mode/setting is the pump.? I hava a oil fired boiler on the ground floor with a 6M circ pump adjacent to it, pumping into the boiler...
  3. J

    CH Pump Problem

    It was years before that maybe around 2014 or something like that so may not have been the "2" but that sticks in my mind.
  4. J

    Once more unto the breach

    Before replacing the pump carefully note the mode and setting of your old pump and match the new one to these settings, as some open vented systems can behave very poorly with air ingress/pump over on the seemingly simple pump change out. I have exactly the same type of combined feed&vent like...
  5. J

    CH Pump Problem

    I wasn't aware of the UPS3 damaging PCBs etc but I remember that the original UPS2? was and Grundfos supplied suppressor leads FOC which presumably cured the problem. Having said that the UPS3 is a really powerful "6M" (6.4M) pump, it will still circulate 1.3m3/hr, 21.7LPM at 6.0M & 60W, almost...
  6. J

    CH Pump Problem

    I was allways a fan of the older type Grundfos but my plumbing friends tell me that the UPS3 especially and generally, all the newer type Grundfos's wouldn't now be their first choice due to relatively short lives and opt for pumps like the DAB Evosta 3, it might be a bit unfair because I...
  7. J

    CH Pump Problem

    If you have a double rad like the one shown with a air vent at (the top) on one end and a blank 15mm plug on the other end, the most economical way of adding inhibitor is to close both rad valves, open the air vent to ensure valves are tight, then slacken one of the nuts a few turns where one of...
  8. J

    CH Pump Problem

    The pumps age is on the front.....PC9913. as you said, week 13 1999.
  9. J

    CH Pump Problem

    Its served you well, time for the boneyard I think?.
  10. J

    CH Pump Problem

    You should be able I think, to remove the impeller assy. where arrowed.
  11. J

    CH Pump Problem

    Yes, why did the chicken/engineer cross the road?, who cares, the system is now working. A ABV will only work to a fashion in these A Rated pumps because as is well known, none have true fixedspeed/constantcurve modes, the UPS3 is the very "worst" one in this regard, see below. On the choosen...
  12. J

    CH Pump Problem

    Your system looks like S plan with motorized valves to the CH and HW cylinder (coil) heating so when the CH or/and HW heating demand ends then both valves close and the pump should run on for a few minutes (to cool down the boiler heat exchanger) but there must ba a path for the water to...
  13. J

    CH Pump Problem

    That's fixed speed II, 5.2M, probably OK, if you start getting any signs of air in the rads etc, change to fixed speed I, 4.2M, which should still be quite OK for your system, you just press the setting button briefly a few times until you get one green LED, as below.
  14. J

    CH Pump Problem

    Ensure that the pump is NOT running at full speed, a UPS3 is a very powerful pump and will invariably create havoc on a open vented system with air ingress, pump over etc if left running in its default/supplied full speed mode. You might care to post a photo of the LEDs while running.
  15. J

    CH Pump Problem

    Why can't you just remove the pump's centre screw and see or feel if the pump shaft is rotating?.
  16. J

    CH Pump Problem

    If your pump was working, shaft seen to be turning??, then remove the head, as suggested, post back with photos, if pump shaft wasn't/isn't rotating then go and get a new pump.
  17. J

    CH Pump Problem

    Suggest, opening & closing them several times, each time when shut give a little extra squeeze up which will help to get a effective seat/seal, when satisfied, remove (with boiler&pump isolated) that pump centre screw again, get a screwdriver or whatever and just push in the shaft a few mm, if...
  18. J

    CH Pump Problem

    The pump should run anytime there is a call for heat from the boiler, the pump may or may not continue running if the boiler cuts/trips out,.. You can see if the pump impeller is rotating by taking out that centre screw, just hold a cloth underneath it when you remove the screw, you might be...
  19. J

    ABVs and Pump performance curves

    Yes, I would think off terminal 10. There is AFAIK, no auxiliary (end) switch on these valves, the only way I can see it failing in the closed position is if it seizes in this position because if the power failed or the motor burned out then it will fail open.
  20. J

    ABVs and Pump performance curves

    Generally speaking, pump overrun is only required when all roomstats (or cylinderstat) are satisfied or the boiler is timed/programmed Off, if so, then its recommended that the pump overruns for a period of time, 3 minutes is often the default time, then circulation has to be maintained either...