Search results

  1. Bigsosij

    Castle caretech 1700 alarm

    Type in the code and it will show the fault on the screen eg F 5 alternating ?
  2. Bigsosij

    Walk Test Showing "1" constantly on Accenta Panel

    Sound like panel is bust then does it do same if u link the zones out directly on the panel
  3. Bigsosij

    Walk Test Showing "1" constantly on Accenta Panel

    All zones are open circuit. I would first rule out any issues with the panel by fitting wire links across 1 or more zones and trying the walk test, of this is ok u will need to determine your zone wiring is correct and make sure devices have 12volts, check if aux fuse has blown. This wouldnt...
  4. Bigsosij

    Pyronix night set, full set, alarm activated. Why?!

    Change the 'set fail' timer to 100 in change timers. Also change 'use level set' to yes in site options
  5. Bigsosij

    Pyronix night set, full set, alarm activated. Why?!

    Whats it show in the logs ? Sounds like set fail timer has expired before your exit timer
  6. Bigsosij

    Pyronix night set, full set, alarm activated. Why?!

    1 App exit volume is programmed seperately under volume control. 2 Program hall sensor as ER (area FX). 3 can do siren test in engineer tests or manager menu
  7. Bigsosij

    Pyronix euro46 fullset issue

    Does the tone change when u open the door
  8. Bigsosij

    Securicor granley vigilant 100

    May be old but still works lol
  9. Bigsosij

    Securicor granley vigilant 100

    I didnt get one of the inside.
  10. Bigsosij

    Securicor granley vigilant 100

    Any one got a manual ?
  11. Bigsosij

    Pyronix alarm - door sensor issue

    Just leave the lod off and it wont go off again
  12. Bigsosij

    Pyronix Enforcer - How to disable/quieten Mains Failure alarm?

    Yes it will work. Keypad will flash orange but no sound
  13. Bigsosij

    Pyronix alarm - door sensor issue

    Disconnect 1 of the wires then the tamper fault will remain so it wont keep going off until your engineer comes back
  14. Bigsosij

    Pyronix euro46

    If u have learned the contacts to inout 17+18 make sure zem 1 is enabled under INSTALL ZEMS
  15. Bigsosij

    Pyronix Euro 46 Home Control 2.0 App

    Users codes / fobs need to be programmed via manager menu on keypad, so no camnot do via app. Each user when programmed via the keypad will be assigned to areas, i.e A - full set, B night set, depending on what areas you have programmed you can assign areas to users accordingly.
  16. Bigsosij

    Pyronix PIR identification

    The only difference with the pet one is the lense filter. If u got cats then wouldnt bother
  17. Bigsosij

    Pyronix Homecontrol History?

    I dont really see any reason to stay connected once the alarm is set anyway lol
Back