Search results

  1. secureiam

    Texecom SmatCom vs ComIP / Which one?

    the comp ip has one connection. This connects to a comport. The smart com has two connections, the smart com part and the comip part. Com ip you just plug it in To one comport. The smart com you would plug it into both comports but use just the com ip part. You can’t use the smart com...
  2. secureiam

    Texecom SmatCom vs ComIP / Which one?

    not cut up the cable. But smart com cable splits into two parts, a 4 core and 2 core. The 4 core provides power and the smart com coms, the 2 wire the com ip coms. You certainly need both to power the unit up. But you can program the com ip module and not the smart com if it’s not in use.
  3. secureiam

    Should I fix my Eurosec CP8L or replace the system entirely with another?

    Just my need to double check the route of the power cable from the panel to the fused spur so you dont screw through it with another box. As for which panels lots of options. Sensors look basic but in decent condition, so if they are working I wouldn't bother changing them unless you want to.
  4. secureiam

    Risco Nova 6 (GT2240) bell box manual anyone?

    S1 off so it draws power from panel and not battery. S5 off standard mode STR uses the bells battery, so no battery no strobe. should be able to remove the battery by unscrewing the wires from battery terminals, I would insulate the ends if doing that mind. If fault wired back to panel then...
  5. secureiam

    Risco Nova 6 (GT2240) bell box manual anyone?

    lookslike its wired as in fig 7/8 not sure on what the dipswitches are set to specifically but dip switch 1 is closest to screw terminals
  6. secureiam

    Risco Nova 6 (GT2240) bell box manual anyone?

    Think I have in my archives found the bell box manual that marries up to the images. Engineer Maintenance Mode. The Engineer may disable the box tamper (built-in bell tamper ring) by removing the 12V+ for 3 seconds. This mode will be indicated by a single flashing LED. To return the sounder...
  7. secureiam

    Should I fix my Eurosec CP8L or replace the system entirely with another?

    As for panels lots of options, the cp8 isn’t a very big panel so how much space is around it may limit your options. Seen them squeezed in and seen others with plenty of space and in an easily accessible area.
  8. secureiam

    Should I fix my Eurosec CP8L or replace the system entirely with another?

    If you’re able to screw something and follow instructions. Maybe look at diy. Or look at having a preconfigured panel. So all you have to do is fit it up and follow some basic instructions. Then test?
  9. secureiam

    Decom Banham alarm

    Don’t see the fused spur. Is the bellbox wireless or hard wired? I can see a cable in the corner but don’t know what it goes to, looks like it goes downward from the enforcer panel.
  10. secureiam

    Risco Nova 6 (GT2240) bell box manual anyone?

    very misguided interpretation. as long as you aware of the potential consequences of removing the battery and or removing the tamper function and can live with it it’s your choice. Removing the battery does not affect the tamper switch at the bell box from activating the bell. If your going...
  11. secureiam

    How Omit a Zone in Pyronix Enforcer?

    If it’s in the draw and not being used you want to delete it off the system and remove the battery from the device.
  12. secureiam

    Decom Banham alarm

    So a pictures may help give you more specific advice on decommissioning
  13. secureiam

    Decom Banham alarm

    Banham is an installer as far as I am aware
  14. secureiam

    Should I fix my Eurosec CP8L or replace the system entirely with another?

    looks like a keypad failure of some kind, replacement keypads are available new old stock, I have 2 in the office for the example but these are not for sale but for customers that may need them that have this panel. I would look t replacing as cost wise you can get a new system with...
  15. secureiam

    Pyronix Service Required

    Check event log. If going in and out of engineering doesn’t reset it maybe you don’t go into engineering or issue still exists ???
  16. secureiam

    Risco Nova 6 (GT2240) bell box manual anyone?

    https://docs.rs-online.com/37cd/0900766b806aee50.pdf . Only manual online I have found for the Nova 6.
  17. secureiam

    Risco Nova 6 (GT2240) bell box manual anyone?

    Agreed moving the battery from the bell means it’s easier to down power from the panel at 4am to stop it ringing. But it doesn’t stop the tamper setting it off at 4am if it’s currently triggering the bell. Waking up, getting to the panel to disable estimated time to do so is 5 minutes, but if...
  18. secureiam

    Risco Nova 6 (GT2240) bell box manual anyone?

    so you want to disable the tamper switch and the battery backup inside the bell box? you would need to bypass the tamper switch so that doesn’t register. You can remove the back up batteries from bell boxes, on many bell boxes turn off the battery backup, with a link. Don’t have a manual...
  19. secureiam

    Texecom Cloud Subscription - What is it?

    Can’t say as an installer I am a fan of the cloud variant and prefer Wintex hands down and ricochet monitor. The health check isnt much use to me as an installer unless I have gold membership and I don’t think it adds value to what I offer. Larger companies however the gold membership works...
  20. secureiam

    Texecom connect / smartcom issue

    Alas this is something that bugs the hell out of me with all manufacturers. I like to know why, not just how to fix blind. Alas not many that are helpful
Back