  1. I

    Baxi 100 HE with intermittent ignition lockout

    had a similar problem with a biasi boiler,condense froze and water backed up and the electrode got damp,boiler was still trying to ignite with electrode sparking but not igniting,at first glance i thought it was the gas valve but after checking it i found it was working fine so i changed the...
  2. I

    riello rs burner

    i have recently been asked to service a buderus ge315 with a reillo rs burner on it,i have always just done domestic boilers so am not sure how different it is to service the burner,i know how to clean out the 315 so dont need help there,any help appreciated,
  3. I

    optimax 25 s

    lads having a problem,f34 flashing on the front,boiler works and then all of a sudden it stops and flashes f34,any suggestions? thanks
  4. I

    gas question

    how do i become a member of the cc if i am gas registered in ireland
  5. I

    ferroli optimax problem

    i did and they didnt bother getting back to me!!!!very annoying
  6. I

    ferroli optimax problem

    i am an rgi in ireland but for some reason i cant join the cc as they dont recognise my number,so if you cud elaborate holty i would be grateful
  7. I

    ferroli optimax problem

    hey lads, having a problem with a optimax 25s,its flashing a fault f02,any ideas thanks ps its a heat only boiler and an open vented system
  8. I

    have problems after removing a radiator

    First turn the power off then turn off the valves each side of the pump and then open the screw put a small towel under it so no water damage gets anywhere,turn on power for a couple of seconds and if you cant see it moving try gently putting in a screwdriver to see if its moving or try to move...
  9. I

    ensuite pipework question ?

    i agree with mark,i have seen this done on many houses and if the worse came to the worse with regards rodding you could always remove the toilet and rod it from there although that would be a last option to try,i would assume that there is a manhole close by which should make rodding handy,i...
  10. I

    HELP!!!!!!!

    cheers slugbabydotcom
  11. I

    HELP!!!!!!!

    thanks for replying john
  12. I

    HELP!!!!!!!

    Hey lads, i have been a member here for a while now and am a registered gas installer here in ireland,i am having trouble trying to get in to the gas fitters forum as i dont think they can recognise my rgi number as i am registered in ireland,should i try putting my companys rgi...
  13. I

    potterton suprima 60

    thanks for the replys lads,the hot water and heating come on at the same time as there are no motorised valves to seperate one from the other,i didnt reallt notice whether the rads where getting too hot to touch to be honest with you mick
  14. I

    potterton suprima 60

    the boiler heats rads for the 15 to 20 minutes then goes to lockout,the pcb is the newer enclosed type,after the twenty minutes are up the boiler then goes to lockout and has to be maually reset,
  15. I

    Fixing a semi recessed basin to worktop

    hopefully he used tec 7 as it wont go anywhere when that sets properly
  16. I

    potterton suprima 60

    hey lads, having a problem with this boiler lads,the boiler will run for 15 to 20 minutes and then goes to lockout,i changed the high limit stat and problem has continued any suggestions would be great
  17. I

    hey lads, have a problem with a suprima 60,boiler runs for 20 minutes and then goes to lockout,i...

    hey lads, have a problem with a suprima 60,boiler runs for 20 minutes and then goes to lockout,i changed the high limit stat and problem has continued,i dont think that the heat exchanger is blocked either
  18. I

    boiler staying on!!!

    Actually havent had a problem with it other than this,how could it be the stat?I thought it was a decent boiler!
  19. I

    boiler staying on!!!

    potterton suprima 80L NUM:LMVO43200239BP
  20. I

    What's the best location for a CH thermostat?

    down the hallway away from the front door as the draught from the door will constantly keep it cool