Your notes show both switches as having 4 holes across the top and 5 across the bottom.
I can't see the photos of the new switches very well but it looks to me as though the upstairs one has 4 holes across the top and 5 across the bottom.
As JohnD says you have to be very careful about...
I'm afraid you're not going to like this. There's a thread which has similarities to your question:
https://www.diynot.com/diy/threads/soakaway-question.635363
One of the replies in that thread says that it's really up to what your (and your neighbours) deeds say. In that thread the deeds...
BC is Building Control, it can be the Local Authority or a private company, they sign off that the work was done according to the building regulations.
If by that you mean there's a switch which controls only the fluorescents then I believe you connect the "floating" black in with the neutrals.
When you supplied 240V to the fluorescents then they had no neutral connection so (what should have been) their neutral wire went up to 240V.
That isn't what securespark was asking. He's interested in whether the (20A, I think you said) MCB in the CU (aka fusebox) has 2 (or more) wires in it.
Just a suggestion, do as Harry suggests in #3, but use 80mm pipe below the new hopper.
Doubtless there are other suppliers of such pipe, but one is:
https://www.drainageonline.co.uk/above-ground-drainage/guttering/floplast-guttering/floplast-80mm-round-plastic-downpipe/80mm-round-downpipe-x-4m-rph4
My guess is that the top pipe was originally installed for ventilation, but (obviously) could be used for other things.
I reckon you've got a Buchan Trap (I expect there are other names/makers); is there always water in the outlet? If so, that's a U bend and above the outlet there's a second...
I believe that Military time is Z time and Zulu is in the Nato phonetic alphabet (Alpha, Bravo etc.) for Z. UK Military time is GMT, I couldn't say for definite about other countries. but Unix documentation talks about Zulu so I'd assume that the American military does as well.
Yes, each FCU will limit the current in the spur wire to, at most, 13A (largest fuse size). At that point I believe you're safe to use 1.5mm T&E for the spur cable.
(I've, pedantically, changed your quote to say "an", not "and")
Does the toilet cistern have a separate overflow pipe?
Comparatively old toilets usually had a side inlet on 1 side and the overflow in the corresponding position on the other so you could arrange the inlet to be whichever side suited you best. If it's easy to take off the cistern lid, look...
I take it you mean the light controlled by terminals COM1 and L11 is working correctly. If so, I'd suggest swapping the long brown that's in COM2 with the one that's in L22.
Also, it looks to me that it's a metal faceplate so you must earth it using the earth terminal to the right.
My guess is that it's a Buchan Trap (I believe there are other names / manufacturers). The idea is that normally all the water passes through the U bend, so yes there should always be standing water. There should be a removable plug in the upper pipe, if the U bend blocks and water builds up...
If you've got the Flow Temp set to 55C then the boiler will burn sufficient gas to heat the returned water (at whatever temp it's at) to 55C, so when the water is only going through 2 rads the boiler will burn less gas as the returning water will be at a, relatively, high temp.
I assume you...
I needn't have worried, I was concerned that the fins would try to push the plug outwards, but a good firm push was all that was needed for the plug to stay right in.
I want to cap off a 110mm pipe using a McAlpine DC4-BL (link):
https://mcalpineplumbing.com/plastic-chrome-fittings/drain-connectors-boss-connectors-roof-flashing/dc4-bl-drain-connector-blank-cap
Judging by this drawing (link)...