  1. S

    PIR's & smoke detector recommendations for Galaxy G520

    Title says it all. I'd like to integrate some smoke detectors into my system and fit a PIR in most of the rooms. What are your preferred brands/model no? Thanks -slip
  2. S

    Door Force error Keyprox (Max)

    No cuts or faults with the cable. This is a recent edition MK7 Keyprox with built-in reader. There is no physical or electronic connection to the door. It looks like the alarm condition is being generated by the Keyprox - I just tried swapping it out with another very old Keyrox and no alarms so...
  3. S

    Door Force error Keyprox (Max)

    I am getting repeat alarms being triggered. It looks like one of my Keyprox is generating the error. On the keypads I get the following error: DOOR FORC A1 On inspecting the logs it I see DOOR FORC MAX 20. This is the address for one of my keyprox's. I have checked the keypad and can't see...
  4. S

    New Galaxy Dimension - a few questions

    Hi Guys, Just a quick line to wish you all a Happy New Year and let you know that I have now resolved all my issues to date. I would like to say a big thank you to you for your help - I would have struggled without it. I still have the Galaxy sitting on my bench where it will remain for the...
  5. S

    New Galaxy Dimension - a few questions

    So I cleared all group programming and started from scratch again. Issues 1 & 2 are now solved. I had a couple more keyprox's delivered yesterday and have figured out how to assign them to groups. Only issue I have left is that I can't assign groups A3 & A4. I think the error I got was something...
  6. S

    New Galaxy Dimension - a few questions

    Hi Chaps, Apologies for the late reply as I have been away on business. Thanks for that pointer Scott. You were absolutely right, group exit times on Groups A2-A5 were set to zero. Changing these to 30 sec allows the system to set now. I do have a few more questions for you guys. 1. Now when...
  7. S

    New Galaxy Dimension - a few questions

    Apologies for the constant questions. Mmm, now seem to have a new problem. Set using PIN+A Timed set starts Close final Keypad, double beeps & says SYSTEM SET, but continues to show all the countdown bar dots & a constant tone is also emitted. The panel reports back via SIA and the Gx app that...
  8. S

    New Galaxy Dimension - a few questions

    Hi Ultomoat, Yes I have a full set of manuals. That's the problem though, I don't get the group options when setting PIN+A. 63>1>1>1 - Group mode is enabled Zones are assigned to groups eg: 52>1>2011A2 I did look at selfmon and was one of the options I was considering when I found it this...
  9. S

    New Galaxy Dimension - a few questions

    Although still can't figure out how to set/unset the groups! If I enter PIN+A Group A1 sets, Groups A2-A5 remain unset If I enter my PIN+ENT then all groups unset. I can set/unset all the groups individually via Crestron using SIA. I believe I have have set up Group choice correctly...
  10. S

    New Galaxy Dimension - a few questions

    OK, Think I figured out the groups... 52>1>zone number>10>Group number Don't know why that was so hard yesterday :)
  11. S

    New Galaxy Dimension - a few questions

    Also as an aside, the Gx RemoteControl app is working as expected now. I have that set up through DNS so now works on mobile data and is surprisingly responsive. Any recommendations on an add-on for TXT? These look quite good...
  12. S

    New Galaxy Dimension - a few questions

    1. Unfortunately I don't have RSS so I hope there is some way of doing this from a keypad. 2. I have a Reason8 that I was planning on wiring to the outputs on the P026, will this still trigger? I take it that I can program the +RIO XX TAMPER to trigger some kind of alarm in the main house -...
  13. S

    New Galaxy Dimension - a few questions

    Hi Scott, Thanks for the info. 51.65.n only allows me to set the options between level 3 - 7. Setting each of these to level 6 now brings up a Manager Reset Required which is much more wife friendly as she will not have to deal with the Engineer menu at all. This may not be quite so secure but...
  14. S

    New Galaxy Dimension - a few questions

    Opps, Network switch was turned off. Seems to have fixed it now - hopes!
  15. S

    New Galaxy Dimension - a few questions

    GalaxyGuy, please check your inbox. So I just powered the Galaxy up again on my bench today and now have an error: COMMS LINE FAIL +LINE FAILCOM 4 What does that mean?
  16. S

    New Galaxy Dimension - a few questions

    Did notice that once I had set up the remote access correctly, system seems sluggish now - entering PIN numbers take about 0.5-1s for the *'s to appear. Was instantaneous before. -s
  17. S

    New Galaxy Dimension - a few questions

    4. OK may be getting somewhere. 56>4>03>1>4 Then 56>4>03>2>1 - This was set to 2 (manager authorise) Will leave the system for a couple of hours and see if it holds. Regards -slip
  18. S

    New Galaxy Dimension - a few questions

    Thanks once again for your time and effort. 1. OK - makes sense now you explained it 3. So set REMOTE RESET=OFF Now if I simulate a fault condition (pull battery power for instance) I now get a message 'CALL ENGINEER RESET REQUIRED' Is that normal behaviour? I can clear it by simply entering...
  19. S

    New Galaxy Dimension - a few questions

    Galaxy Guy, Thanks for the prompt response. 1. That worked - Why would they do that? 2. Great news 3. 51.67 takes me to 51=PARAMETERS.67=LEVEL FORMAT which then gives me two options> 1. EN.Galaxy 2. Galaxy. I found 60=ENGINEER 2>67=REMOTE RESET 4. 20.23 gives me the following: GROUPS A-D...
  20. S

    New Galaxy Dimension - a few questions

    Having looked at various forums I figured to post here as there seems to be a lot of worthwhile experience without some of the attitude I have seen on some of the 'professional forums'. So greetings everyone - first post. I bought a new Galaxy Dimension G520 off ebay. Although I don't work in...