  1. MrV

    Vaillant Hot water Problem

    When was it last serviced and has the diverter valve ever been replaced? Are you referring to the reset button?
  2. MrV

    Vaillant VCW 242 EH diverter moves wrong way for CH

    Are you a Gas safe engineer?
  3. MrV

    saunier duval therma classic

    They're both "Failed to ignite" faults. Either your gas supply is out or you have a boiler fault that needs looking at by a professional as Dan said.
  4. MrV

    Vaillant EcoTEC

    Nah.. I just got wheels fitted to my Zimmer.. 8) Age have no relevance here Bunnyman... And I truly believe in that you can't put a price on proper Professional experience..
  5. MrV

    Vaillant EcoTEC

    :( Sorry Bunnyman.. :(
  6. MrV

    Vaillant EcoTEC

    Yeah, that should be fine. Power on, Mains water off so it can frost protect itself whilst you're away. Does it have Vaillant controls or Other?
  7. MrV

    Vaillant Controls

    The 600 series is different. It has an orange and black lead with a plug on the end that already exists on the harness in the left side. You snip the plug off and use a block connector to connect the sensor.
  8. MrV

    Vaillant Controls

    In order to fit the standard NTC sensor (VR10) to the ecoTEC plus open vent boiler an additional harness is required (as shown below) this can be obtained by getting your installer to contact Rochester Technical department and ask for the ecoTEC open vent, cylinder NTC harness. The harness is...
  9. Untitled

    Untitled

  10. Pics

    Pics

  11. MrV

    Vaillant Controls

    The vr10 semsor does go back to the boiler as the wiring diagram says. There is a special plug available for this connection to make the connection possible on the 400 series ecoTEC. Your suppliers merchant may be able to obtain it for you, i'll try to find out how else it can be ontained...
  12. MrV

    Vaillant VRC 430f cycling issues - a solution?

    Reducing D2 will increase cycling.. and it's not a set value. There are a few variables in the algorithm that will alter the anti cycle time so meddling with it, and especially lowering it will make it cycle more. All the boilers mentioned above share the same startup logical sequences. It's...
  13. MrV

    Water leaking from heat exchanger in gloworm 30sxi boiler.

    If you are sure that you can see that it is leaking from the flue and running down the front of the heat exchanger, then it will very likely be one of the seals in the flue system. Generally caused from installation where the installer cuts the flue but doesn't clean the rough cut which damages...
  14. MrV

    Vaillant Issues

    True for sure. But it will greatly improve it and enable you to reduce waste energy on the central heating too, and if your coil rating is much lower than the minimum capacity of most boilers then the cylinder seriously needs upgrading too, as you have already said.
  15. MrV

    Vaillant Issues

    Misread ya Alec. Soz there being helpful
  16. MrV

    Vaillant Issues

    Yup. Ebus controls have this ability to do so. Can tell you how to in cc if you wish to know.
  17. MrV

    Vaillant Issues

    If you get your system design issues sorted and you still have issues with heating your cylinder and it continues to annoy you, you can use a valiant controller and module. It will cost you extra of course, but one of the main advantages it can offer you, which NO other controller can, is that...
  18. MrV

    30cxi display fault

    Yes, but as it's in the standard forum... Are you a member of CC?
  19. MrV

    Vaillant Eco+ switching on and off

    Hi, i'm guessing that what it is you are hearing turn off and back on when you say the boiler runs, is the Pump. The pump has a minimum 2 min overrun after it has reached temperature and the flame has gone out. It will then carry out a quick self check and if external demand still exists, it...