Search results

  1. X

    Bonding agent for fibre cement tiles

    PVA not really needed just DON'T use only yellow sand in the mortar mix it will drop out of the bed in time.i like a 3x1 mix!! 1 cement 1 yellow building sand 2 brown building sand which will give it strength and feb mix not squezzee liquid...
  2. X

    RavenHeat CSI 120T Low NOX Boiler

    No boiler had numerous problems from day one.Electrics at first then over heat stat. banging on got worse just took it out was that peed off in a rental property so fitted a new ideal with 5 year warranty sweet as a nut compared to the ravenheap..
  3. X

    RavenHeat CSI 120T Low NOX Boiler

    please tell us your findings i had a similar problem.replaced boiler in the end as could not find fault
  4. X

    Fascia, Soffits & Gutting Cost

    Till you have an accident off them :shock:
  5. X

    Eternit Tile

    That's why we favour cembrit over eternit they don't get the white staining like the eternit's when wet..And there cheaper bundled better
  6. X

    Best roof membrane to use?

    Roofshield is better than tyvek
  7. X

    Ridge tiling job in 1 day?

    best mix i find is 2 yellow 1 brown building sand 1 cement goes rock hard.not keen on all yellow sand mix.bed and point as you go.feb mix is the way to go.only 6 quid a bottle
  8. X

    Is this normal? Tiles around velux look messy

    The tiles a kicking up at the sides of the velux because they will be sitting on the sponge on the flashings.we always remove this because getting the tiles to sit right is nigh on impossible due to the thickness of sponge.or trim it down,but with a flat tile like these better to remove it..
  9. X

    Roof looks awful since Velux fitted.

    pictures of the job would help??
  10. X

    Self employed plumbers

    its not just plumbers that are in short supply. im over the moon main line house builders can't get trades as sites are getting busy now.They dropped the house prices so they kept chopping the trades prices.And a lot of them have moved on. With no apprentices being taken on i can see the...
  11. X

    ravenheat csi 120 problem

    easy tiger,actually it was a freind who is on th GS registar.no money changed hands i done his roof and he put the system in. just trying eliminate things. he is going to drain system and put a cleaner in to see if that can sort it..
  12. X

    ravenheat csi 120 problem

    it was a full system fitted just 4 month a go. could it be scaled up in that time.
  13. X

    Tiles/Slates to use for 12.5 degrees pitched roof?

    you could use onduline sheets,then use slates at a 100-125mm lap the onduline will keep any water out. or ply wood sheet the roof and felt it pour and rool or torch on. counter batten then felt and batten it before slating or tiling it
  14. X

    ravenheat csi 120 problem

    my boiler has started making a loud banging and grinding noise googled the problem and said it could be an airlock,as the boiler has automatic vents to prevent this, could it still be air in the system..
  15. X

    Dry Verge systems

    continous dry verge is better than individual units in my humble opinion comes in 5m lengths and a jointer is available if the spar length is longer. profiles vary from small tiles to a deep profile tile or a small profile for slates..
Back