Search results

  1. EFLImpudence

    Pulled from another thread

    FFS. I just think people should be corrected when they use the wrong words whether its calling 'half a pint' a 'gill' or using 'of' instead of 'have'. It's not a great debate involving ancestors.
  2. EFLImpudence

    Cable size for two ovens and a hob from extension CU with 6mm supply

    Will the new kitchen be the main house's kitchen or a separate one for the extension?
  3. EFLImpudence

    Cable size for two ovens and a hob from extension CU with 6mm supply

    Ideal. Do that then. No need. It could but 6mm² would do - probably 4mm² but people use 6mm² for historic reasons. Yes, very silly - especially as one would be in a bedroom above the kitchen.
  4. EFLImpudence

    Pulled from another thread

    Amazing! Perhaps not deliberately obtuse..
  5. EFLImpudence

    2 way switch on stud wall (image included)

    Here's one I made earlier:
  6. EFLImpudence

    Pulled from another thread

    I see what you have done there. You want yes/no answers but include so many qualifiers which require explanation it makes yes/no impossible. I will just say that I have said many times we cannot alter what has already happened but there is no need to continue having the language decided by the...
  7. EFLImpudence

    Lighting earth issues - could I just run a fused spur from the power circuit

    Yes, people will do that. However 1.5mm² T&E has a maximum current carrying capacity of 20A - a lot of LEDs.
  8. EFLImpudence

    Lighting earth issues - could I just run a fused spur from the power circuit

    Yes, nothing wrong with doing that. No limit on the number of lights. Fuse rating determined by rating/size of cable. It could be argued both ways, so choose the way you want. Go ahead.
  9. EFLImpudence

    Pulled from another thread

    I think you are being deliberately obtuse.
  10. EFLImpudence

    Pulled from another thread

    I understand what you are saying but I don't understand why you think as you do. Except in the instances where you say there are. Yes I would think that crazy but I also think the other errors are equally crazy and don't understand why you do not. . People's stupidity becoming the majority...
  11. EFLImpudence

    Pulled from another thread

    I was - but I don't really understand your views . Why then, is it different than using any other word wrongly? Well, it sort of has and is. It means a tenth - decimetre etc.. Probably the ignorant used the word wrongly then more copied them - the same as happens now when people spell and...
  12. EFLImpudence

    Pulled from another thread

    Yes, but my point was for John who seems to think it is 'evolution' and a good thing whenever I point out such mistakes.
  13. EFLImpudence

    Pulled from another thread

    Mmmmm. Surely if people know what is really meant then it is alright and could eventually become correct. Is that not how it works?
  14. EFLImpudence

    RCD tripping

    What is there to disagree with?
  15. EFLImpudence

    Cable size for two ovens and a hob from extension CU with 6mm supply

    Ok. No. It is a flawed concept. Anyway, I, at least, am not even sure that what you want to do is present-proof.
  16. EFLImpudence

    Cable size for two ovens and a hob from extension CU with 6mm supply

    Ok, so is it easy to run a 10mm² from bedroom to the switch?
  17. EFLImpudence

    Lighting (first fix) T&E to flex / outlet plate

    It's not really a protector - just a guide and/or a holder. Not if it or just the cable will stay in place without clipping.
  18. EFLImpudence

    Cable size for two ovens and a hob from extension CU with 6mm supply

    I know but what about the other way round? I am about to build an en-suite bedroom extension (with see above), can I power the bedroom consumer unit from the house cooker circuit in the next room? The answer will obviously be the same but I will leave it to someone else to say "Yes, carry on".
  19. EFLImpudence

    Cable size for two ovens and a hob from extension CU with 6mm supply

    I'm confused about the origin of the supply cable.
Back