Search results

  1. A

    Replace red and black 10mm cable to loft conversion?

    you don't even need the labels these days
  2. A

    Replace red and black 10mm cable to loft conversion?

    A radial will be fine for a loft. 2.5mm cable, 20A circuit protection. But if what you currently have works for you, leave it alone.
  3. A

    Loft lights: 2 circuits

    OCD
  4. A

    Loft lights: 2 circuits

    surprised you didn't blank out the .5
  5. A

    Loft lights: 2 circuits

    I mean its not wrong. That is how you would do it with ceiling roses, but you have LED battens. (so do the junction in them) Do you really need 2 switches for them? LEDs don't consume much. Be simpler with one switch and just take one lamp feed from the other. The other way to make it really...
  6. A

    Trying to upgrade house fuse to 100A

    what the lidl version or the real version ?
  7. A

    Trying to upgrade house fuse to 100A

    and supply Tea and Jaffa Cakes ?
  8. A

    5w 700lumens Vs 7w 720lumens

    Check the life / hours for both.
  9. A

    Kitnhen spurs

    2.5mm can handle 27A. You don’t want a 13A fcu as it will overheat. You could use a 20/30/45A switch if you want. I would. To ensure the fridge can run if there is a Cooker fault. I’d fit a 25A mcb What brand cu is it?
  10. A

    Multiple CUs with 25mm and 16mm tails. RCD specs

    RCDs don’t limit current, so that’s not going to make a difference
  11. A

    Trying to upgrade house fuse to 100A

    what cable is between the meter and your CU ? Black SWA ? 2 Tails. grey/brown/blue ? photos help.
  12. A

    Help needed with garage electrics

    The owner doesn’t have an EV at present and may never get one.
  13. A

    Help needed with garage electrics

    Who needs a trench when there is already a perfectly good cable present?
  14. A

    Help needed with garage electrics

    waste of time/money/effort/copper to put another cable in
  15. A

    More domestic 2 way

    It’s been mentioned before on here. Don’t know what advantage is of taking 2 3+e to the rose?
  16. A

    Rewire.

    Which is just a dot on my phone?
  17. A

    Rewire.

    What good point did I miss
  18. A

    Help needed with garage electrics

    Being sensible, I would put a 2 way metal CU into the garage. Metal one to future proof. Put it near the ev charger or where cables enter the garage. It must have an RCD. 6A mcb for lights 16 or 20A for sockets. Should you want to use the ev charger in the future you can talk to a spark. But...
  19. A

    non basec cable

    The cpc looks so shiny to be so old the insulation has faded
  20. A

    RCBO tripping - identify likely location - help.......

    If neutrals were looped at the switches, wouldn’t that avoid having to get up a ladder? (Except maybe, the room with the fault ?)