  1. D

    Odd underground pipe? Can anyone identify?

    My guess, and it is a guess, just badly made. When you cut it out it may be perfectly normal inside
  2. D

    Odd underground pipe? Can anyone identify?

    The flexi seal adaptor couplings with a jubilee clip come in a variety of sizes. Sure you will be able to find one that fits. https://www.flexseal.co.uk/assets/Data-Sheets-Folder/Flexseal-Adaptor-Couplings-Datasheet.pdf
  3. D

    Baxi 105e

    It is diverter valve not properly closing the heating circuit. It is a mechanical item so should be straightforward. You can buy a complete exchange refurbished valve for £45 if you can not see the problem.
  4. D

    3way heating and hot water issue

    Yes replacing the actuator head IF it is in fact the problem. It could still be cylinder stat, programmer or room stat. What I was saying, with valve manually opened, remove cylinder stat to keep hw &ch running pending test & replace failed component.
  5. D

    3way heating and hot water issue

    To keep it going just remove the cylinder stat from the cylinder
  6. D

    Hot water venting cold water header tank

    So nothing is connected to the coil in the cylinder?
  7. D

    Structural issue or slant shower base?

    Have you removed the shower door? Your video doesn't quite travel far enough to tell. Reason I ask is, the sealant hidden behind the door frame is a very important part to get right.
  8. D

    Ferroli Optimax HE31C

    Thanks Duz, now we are all hoping that we never need it!
  9. D

    Hot water venting cold water header tank

    Is your heating tank fed or sealed system?
  10. D

    Ferroli Optimax HE31C

    Can you put a copy on here? May be useful to someone
  11. D

    Ferroli Optimax HE31C

    Sorry, so it doesn't. I have this, not much but may help:
  12. D

    Ferroli Optimax HE31C

    If it is the Optimax HE 31C
  13. D

    Radiators not hot enough

    The boiler shuts down when it is up to temperature (Return is hot) so it is circulating around either the cylinder or the "easiest" rad and going back to boiler. Is it any better on heating only? Is there a rad that gets particularly hot? Is there a by-pass, perhaps in the airing cupboard?
  14. D

    keeps shorting

    While the power is OFF, remove the cover on the side of the pump and see how wet it is in there. If it has water over all the connections this will cause the trip to blow. Unless water can have dripped in there from above, tracked along the cable, this will be a new pump.
  15. D

    No water supply, what happens when the hot water tank in the attic is empty?

    Running out of ways to say this.Boiler is still full of water and coil in cylinder is still full of the same water. Cylinder is in fact still full of water, not that that matters. Boiler will not be aware that it has heated a cylinder full of water which you can not use as you have no cold water...
  16. D

    Error code E5

    The over ride button on the programmer? Heating is on twice a day and due to come on at 5 o clock You come home at 4 and are cold. Push the over ride button & heating comes on now but will go off at 10 as normal.
  17. D

    No water supply, what happens when the hot water tank in the attic is empty?

    The cistern in the attic stores the water which feeds the Cylinder. The cylinder supplies the hot taps. The water in the cylinder is heated with a coil which is full of system water which is heated by the boiler. Yours may be tank fed as below or pressurised (filled from the mains). Either way...
  18. D

    No water supply, what happens when the hot water tank in the attic is empty?

    Heating system water and domestic hot water are completely seperate so when your cistern runs dry, central heating circuit is still full. You can therefore leave heating & water on even when domestic tank has run dry.
  19. D

    £500 Tool To Make Your Own Copper Pipe Tees!

    I think that they silver solder everything over there dont they