  1. D

    Discharge from Boiler Cupboard Ventilation Grate

    That looks as it should. No signs of water running down outside then? Is the air vent still open to the outside? It is possible that a small leak on the boiler, running down hot pipe is evaporating & then condensing on the cold spots so you could dry up everything, leave door open & heating off...
  2. D

    Discharge from Boiler Cupboard Ventilation Grate

    I can't make out that first photo. Doesn't look right but then I am not sure what it is
  3. D

    UFH added, now boiler occasionally trips out

    Was the system dirty? If so the maybe muck in pump impellor causing poor flow. Are your pumps set up correctly? Is flow & return at the boiler very hot when it overheats, are they much the same temperature, is pump still running or has it stopped?
  4. D

    Discharge from Boiler Cupboard Ventilation Grate

    It sounds less likely that it is your boiler as it has been checked during the period that this has been happening so that is good. Have you had a look outside, water running down wall from guttering, downpipe, overflow etc. then try to get a look in cupboard in flat above.
  5. D

    UFH added, now boiler occasionally trips out

    Although the zone valve to the UFH is open, it could be that the blending valve is moved all the way to full re-circulate therefore there is no flow through the zone valve. The auto by-pass ought to be sufficient (assuming that you have at least 4m of pipe between boiler & airing cupboard. You...
  6. D

    UFH added, now boiler occasionally trips out

    Is the arrow pointing in the direction of flow or is it perhaps fitted the wrong way round?
  7. D

    Discharge from Boiler Cupboard Ventilation Grate

    First, has she got a Co detector? Quite possibly a leak from above but gas boiler surrounded by condensation is a bit disturbing. On the flue outlet above boiler has the little plastic cap been replaced after the last service or is it open?
  8. D

    Simple Q. regarding braided tap hoses...

    I have only dealt with 3 failed hoses. All of them after midnight, one of them I had to get the woman to come & pick me up cos of the drink. They don't just drip when they fail they are just open ended 15mm pipes.
  9. D

    Under gassed boiler

    If the gas safe certificate did not mention the undersized gas pipe then you could draw this to the attention of your solicitor who handled the purchase although from what I see of these things you will be unlikely to get anywhere unless you get £200 compensation & a £1200 solicitors bill. The...
  10. D

    Elbow, tap connector and check valve - not compatible

    The shower below is a Mira Coda so not yours. All the bar mixer showers that I have dealt with have NRV fitted as below. It is the little cylinder that is held in place with a circlip. Many showers do not have a circlip so I have known them fitted without the check valve or with only one. If you...
  11. D

    Elbow, tap connector and check valve - not compatible

    https://www.showerdoc.com/ultra-group-check-valves-pair-for-twin-and-triple-valves-saov15
  12. D

    Elbow, tap connector and check valve - not compatible

    The tap connector has a little spigot inside which retains & supports the washer. This spigot will be too big to go inside the male elbow therefore the washer is not compressed between the mating faces. Therefore no seal. Are you sure that your shower valve does not have built in check valves...
  13. D

    Heating not going off on timer

    Your pump is running, the boiler is firing, you have heat at the diverter valve and can send it to cylinder. If you switch valve to heating does the heat start to flow down the heating pipe? If not have you turned all your radiator valves off?
  14. D

    Heating not going off on timer

    It can only be one or the other??
  15. D

    Heating not going off on timer

    Put your pump on 3 Did you Turn cyl stat down, valve moves to H and heating pipe should now be getting hot? If not, remove head from valve and turn the spindle manually. You should be able to divert the heat to water or to rads.
  16. D

    Heating not going off on timer

    Again crossed posts, I am beginning to doubt that your pump is running. If it has a big screw in the centre removing this, there will be a bit of water so have a rag handy, you can put a screwdriver on the end of the spindle and feel if it is spinning or help it to start
  17. D

    Heating not going off on timer

    Spindle only turns 90 degrees so not possible and head only fits in one position. Turn cyl stat down, valve moves to H and heating pipe should now be getting hot? If not, remove head from valve and turn the spindle manually. You should be able to divert the heat to water or to rads.
  18. D

    upstairs bathroom existing soil pipe alteration advice

    https://www.google.co.uk/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&uact=8&ved=0ahUKEwjr_-f-sI_ZAhWKDsAKHXglBI8QtwIIcTAA&url=https%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3D4CWtom0IFmQ&usg=AOvVaw2Qz2LBZP24V5zgk_gTgQOl
  19. D

    Heating not going off on timer

    Mine and yours were posted at the same time. Your boiler is firing then, any heat at pipes by diverter valve? Any heat at pipes by boiler? Diverter is behaving as it should isn't it?