    4mm T&E in insulation

    Are you saying the 37A Ref method C is correct and and the other reference methods are incorrect? There is a glaring error (basically the 50% reduction in CCC) in the tables. I have never seen an erratum to correct the table. Of course the regs have never has a misprint before have they?
  2. B

    4mm T&E in insulation

    So which bit is incorrect?
  3. B

    4mm T&E in insulation

    Table 4D5 gives all reference method 103 CCCs as exactly half of the reference method C CCCs apart from 4mm T&E. Table 4A2 does not clear things up. So anyone any ideas why 4mm T&E has a greater than 50% reduction in it's CCC when installed in insulation?
  4. B

    Three 3kW handwashers

    Does this 0.725 rule apply if overload protection is not needed? It's 3 fixed loads that is complicated by a useless installation manual:-)
  5. B

    Could somebody advise on this lighting circuit please?

    And that else is connected to this 3 block of strip connector? Your spotlight?
  6. B

    CU installation??

    Well it's not one of mine. I know that as the spelling on the hand written label is correct
  7. B

    preventing use of electric heaters

    It might do if the landlord has fitted a VPhase.
  8. B

    preventing use of electric heaters

    I have a feeling that the OP is renting out a ****hole.
  9. B

    Picture of the week!™

    I fitted that - what's wrong with it?
  10. B

    Breaking ring main

    I would not have any problems with running the UFH from the lighting circuit. The UFH will need RCD protection - either at the CU or via a RCD fused spur
  11. B

    Breaking ring main

    Yes.
  12. B

    running a heavy load on a fused spur

    Was Bernard suggesting a 4mm spur from a ring final circuit?
  13. B

    My electrician is worried about asbestos

    http://www.esc.org.uk/fileadmin/user_upload/documents/industry/asbestors/asbestos.pdf for those that want more info.
  14. B

    New CU. Post installation questions.

    I totally agree that there may be a reason for not exporting the earth. But putting two RCDs in series (with the suggestion that they are both 30mA ones) when the summerhouse is powered by SWA suggests a lack of thought has gone into the CU swap. Incorrectly labelling the MCBs says enough...
  15. B

    New CU. Post installation questions.

    And would you consider that to be a badly designed installation?
  16. B

    New CU. Post installation questions.

    I was thinking that there would now be two RCDs in series.
  17. B

    New CU. Post installation questions.

    Adding the earth rod seems to be a pointless exercise!
  18. B

    FCU connected to ring main

    The word "only" is not used in 433.1.5. It says that BS1363 MAY be supplied with or without unfused spurs and does not preclude the use of a 20A switch to supply an unfused spur.