Search results

  1. Echo the husky

    Consumer unit keeps tripping ourlt

    I'd expect a little more clearance between live parts and earthed parts than the width of a crumb of bread!
  2. Echo the husky

    Electrolux EWX14450 washing machine

    Yes, label them so you know how to put them back. Insulate the ends of the wires before trying the machine again. Insulation faults in the dryer elements cause all sorts of odd faults with these machines.
  3. Echo the husky

    Leaking Samsung SR-S2026CVW Fridge/Freezer

    It might be stuck with ice. Defrosting the unit should free the panel. It might also solve the leak issue if the drain hole is blocked with ice.
  4. Echo the husky

    Consumer unit Wiring Containment

    I want to know what the switch fuse is for?
  5. Echo the husky

    Is it just me

    I assume he was drunk at the time?!!!
  6. Echo the husky

    Is it just me

    This is a plug on a piece of hire equipment, how it was returned by a builder after he had hired it. All I've done for this photo is remove the cover. This was sent for repair with the complaint of shocks from appliance:
  7. Echo the husky

    Small euro/shaver socket

    That is for switch modules not euro modules which are larger.
  8. Echo the husky

    Small euro/shaver socket

    Careful, a 2 pin euro socket is not the same as a UK BS4579 shaver socket. A 2 pin euro plug will likely be a poor contact fit and get stuck in a shaver sized socket, the euro pins are much thinner and the metal contact caps overhang the pins and cause them to be stuck on the shutters of most...
  9. Echo the husky

    Overheating Dimplex Quantum storage heater

    The sensor measurements should be fairly stable, need to be measured while disconnected from the circuit board, make sure your fingers aren't touching the meter probes as your skin resistance will skew the readings. If both sensors are at the same temperature the readings should be the same too...
  10. Echo the husky

    Friedland door bell and transformer

    Yes the dual sounder one has some PVC wires connected to the terminals rather than just the 2 enamel ones in the photo.
  11. Echo the husky

    Overheating Dimplex Quantum storage heater

    IIRC the tmp sensors are marked on the PCB, they are connected with small 2 pin connectors, a white one and a black one. The room temperature sensor is marked below: There are guides online how to test temperature sensors, and the expected readings for the current temperature, I would expect...
  12. Echo the husky

    I broke the main fuse seal

    If you have a 'smart' meter it will have already reported the loss of power as a fault back to HQ. If they care they might send an engineer to check why the power went down to your house but none of your neighbours. Removing the main fuse isn't allowed by normies but it's worse if you have...
  13. Echo the husky

    What do you call the slotted part that keeps cables from breaking?

    They are apparently available rewirable with a strain relief, but I'm not sure where you can actually buy them. I used to work repairing appliances and items with strain relief boots the flex often used to break internally or the sheath split at the end of the boot rather than at the plug so...
  14. Echo the husky

    Alcove lighting/LED strip advice

    I've not seen many electric clocks with winding holes in them... Here is the one I've had in the kitchen since I restored it in 2019
  15. Echo the husky

    Alcove lighting/LED strip advice

    Or wire an electric clock into it!
  16. Echo the husky

    Overheating Dimplex Quantum storage heater

    Perhaps there is a faulty temperature sensor or a triac controlling the elements has failed short circuit. I've installed loads of these but not had any fail yet to need to do any fault finding.
  17. Echo the husky

    Silicone sealed downlight replacement

    I think this fitting is fully enclosed, but some open type GU10 fittings you can replace the lamp from the loft space above if it is accessible, to save damaging the decorations.
  18. Echo the husky

    Wylex plug in mcb availability

    Is that on Big Clives bench??
  19. Echo the husky

    Wylex plug in mcb availability

    That's the only one I've ever seen in the 23 years I've worked as an electrician. (I've seen the little 2 way 'extenso' extension boards that of course don't have a main switch but never a full sized one) It's not modified, there was no hole in the cover for a switch.
  20. Echo the husky

    Wylex plug in mcb availability

    What about Wylex boards without a main switch? :)