    Economy 7 Water Tank - Timer Switch

    The heated water doesn't go up the expansion pipe (ok the level might rise a bit) the cool water comes from the cylinder not the cold water feed tank, there will be no flow from the cold tank unless a tap is opened. thermosyphon is surprisingly effective, and the water will have no problems...
  2. Echo the husky

    Economy 7 Water Tank - Timer Switch

    The heated water will rise up through the heater via thermosyphon, as it does it draws cooler water from the bottom of the cylinder, heating the cylinder from the top down.
  3. Echo the husky

    Loss of circuit

    Older MEM MCCBs are known for never being able to switch them back on again after they have been switched off. A colleague tripped a 400A(!) Dorman Smith MCCB a while back. We couldn't reset it until it was dismantled and the mechanism freed. The grease used on the moving parts had turned to...
  4. Echo the husky

    Analogue or digital ?

    No not isolated. Most people just use their mobile phones for everything and have now ditched the landline phone. I have FTTC internet. Though one of the neighbors accidentally booked full fiber to my house instead of theirs, so I've had a coil of unterminated fiber cable outside the front door...
  5. Echo the husky

    Analogue or digital ?

    I was moved to BT's 'digital voice' mid last year. No warning, I phoned up to report no phone service only to be told I had been switched over! The new service has been most unreliable, frequently can't dial out, just get error message instead of dial tone, the audio quality is really harsh and...
  6. Echo the husky

    Plug tops / Plug caps?

    I have this very old NOS MK plug and socket. Even back then they are calling it a socket and plug.
  7. Echo the husky

    socket isnt even striaght......

    It's not straight to allow the water to run off.
  8. Echo the husky

    Advisory after new shower fitted

    The photo of the cutout suggests a TN-S earthing system not TN-C-S.
  9. Echo the husky

    Low voltage to shower

    Perhaps you should have had a better sparky out... There is no reason the fault could not have been narrowed down. MCB or pump sounds like clueless guesswork to me.
  10. Echo the husky

    Both rcd,s tripping with faulty light switch

    The main danger is to someone working on the circuit the neutral has been 'borrowed' from. If someone was to isolate the socket circuit, test it dead, it would appear dead. If they then disconnected the neutral wires at some point on the circuit between the consumer unit and the light, say to...
  11. Echo the husky

    Y plan no ch

    As above. Do you have 240v on the grey wire too?
  12. Echo the husky

    What's this (shower arm fixing?) called and where can I get one? (Ed.)

    The one in jj4091s link was closer than mine...
  13. Echo the husky

    What's this (shower arm fixing?) called and where can I get one? (Ed.)

    Something like this? https://pipedreamfittings.com/product/table-d-slip-on-flange-316l-stainless-steel-2/?attribute_pa_size=12&utm_source=Google+Shopping&utm_medium=cpc&utm_campaign=xm01&gad_source=1&gclid=CjwKCAjwrvyxBhAbEiwAEg_KgjUS6k4UKmRMQ0BImOfg_9S1tfPc-SVx6N3YoMRTsyf-csSNEHXV8RoCoGwQAvD_BwE
  14. Echo the husky

    Horstmann HRT2 change to HRT3

    You need to check the wiring. The existing stat appears to be connected incorrectly, and or is using the earth wire as a switched live which is not permitted, the manual also says not to use terminal 2. If you only have 2 wires and earth, the HRT2 and HRT3 models are not suitable as they require...
  15. Echo the husky

    Y-Plan heating and "Last Port of Call" issue with 3-port valve

    That modification would certainly increase the life of the synchron motor as well as save some electric.
  16. Echo the husky

    Y-Plan heating and "Last Port of Call" issue with 3-port valve

    The valve will stay in its last position when the programmer/stat is switched off however if both HW and CH are running and the valve is in the mid position and shut off together the valve will spring return to HW only. If only the CH is running the valve will stay powered and remain in the CH...
  17. Echo the husky

    LED lighting transformer issue

    Those aren't 12V transformers, they are constant current LED drivers, If you plugged the LEDS in with the power on to the drivers you will have blown the LEDs due to over voltage.
  18. Echo the husky

    How old is my cable

    Don't forget the crazy date codes on some old cables, AEI used to use: MAYFLOWERS for 1234567890 e.g. MRLS for 1950 BICC used a similar system but I can never remember that one.
  19. Echo the husky

    Funny one

    Long enough, that cable is a nightmare!
  20. Echo the husky

    Honeywell RSS Update Patch

    Hi, does anyone have a link to or copy of the update patch for the RSS software? I have the patch update to version v7.03 but need v7.04. I was able to download the last update via the Honeywell website but this time I just keep going around in circles. I've tried to register but that part of...
Back
Top