  1. Echo the husky

    gas fire installation

    They get the sack if they don't. They aren't allowed in the loft either so have to throw the cable over the roof...
  2. Echo the husky

    Running 32mm waste through 3x2 studs

    I was serious, it was clearly installed by a skilled carpenter.
  3. Echo the husky

    Running 32mm waste through 3x2 studs

    I can't offer any advise, but that is some beautiful woodwork.
  4. Echo the husky

    Post war UK electrical industry 1946

    Cool. Sadly the only items I have here that are mentioned there are some Bill Radette 3 phase switches. Certainly seen some of the other stuff still in use. Ellison switchgear is nice stuff, and Welwyn vitreous enamel resistors are still wonderful things. I'd also love to see one of those Pyrex...
  5. Echo the husky

    FP200 vs T&E (vs LSOH T&E)

    Some of our jobs involved wiring entire houses in MI. Don't forget those old council houses wired in the stuff!
  6. Echo the husky

    new immersion heater control

    From the photo.
  7. Echo the husky

    FP200 vs T&E (vs LSOH T&E)

    Mineral insulated copper cable (MICC) Lasts forever and looks good when properly installed, no plastics to burn except the sheath, does not ignite, even when severely overloaded, smaller OD, fun to install, robust as hell, cables available with up to 19 conductors. FP200 Cheap, garbage cable...
  8. Echo the husky

    new immersion heater control

    The missing blanks from the normal consumer unit need to be replaced. I guess the space was once filled with the 2 LeGrill MCBs now in the off peak board.
  9. Echo the husky

    What bathroom zone is this light fitting in?

    I can remove the lamp from my bathroom pendant while standing in the bath, and then poke my fingers into the lampholder. My will to live however stops me from doing that. I can also spray it with the shower!
  10. Echo the husky

    Can you identify this consumer unit?

    Some of the first CUs I fitted were like that. How silly things have become now.
  11. Echo the husky

    Grundfos pump still not working

    You changed the silver part too?
  12. Echo the husky

    Grundfos pump still not working

    The UPS2 has a circuit board in it with the speed control electronics in the black part, these are delicate and fail frequently. If the motor in the silver bit is faulty it will kill any replacement circuit modules. The circuit modules often fail as a short across live and neutral, that often...
  13. Echo the husky

    Grundfos pump still not working

    Post a photo showing exactly what part was replaced, I assumed the terminal box you were referring to was the black part of the pump where the wires connect?
  14. Echo the husky

    Grundfos pump still not working

    The ones in the terminal box with the lights on.
  15. Echo the husky

    Grundfos pump still not working

    The electronics are probably blown then.
  16. Echo the husky

    Grundfos pump still not working

    But you used the old motor? The motor windings could be faulty killing the old electronics, now hew new electronics could be dead.
  17. Echo the husky

    Grundfos pump still not working

    Was the entire pump changed, or just the motor? Does the shaft rotate freely through he bleed screw?
  18. Echo the husky

    Can you identify this consumer unit?

    looks like it. It's probably a Legrande consumer unit.
  19. Echo the husky

    Suspect Motorised Valve on Central Heating

    Does the heating valve appear to open and close when heating is turned on and off? When off and closed the little manual lever on the valve should have resistance. It will be free when the valve is open.