  1. B

    Vokera 20 80 RS Flowmatic problem

    Either the pump flow switch or the fan resistor faulty, both easy cheap repairs
  2. B

    Spirotrap Magnabooster?

    It sounds like he was telling u porkie pies, there are no exclusions if u dont get a spiro fitted, but if the water becomes sludged up then you'll get a quote 2 have a powerflush done which is 600 quid, the spiro is fitted to help prevent that.
  3. B

    Boiler pressure keeps rising.

    Listem mate if the pressure is continuously rising and ur not adding any more water to it yourself then the fill loop or twin pass heat exchanger are passing. Disconnect the fill loop if its still doing it then its the heat exchanger passing. The expansion vessel is not faulty.
  4. B

    Potterton Suprima 30 - Replace PCB?

    Call a qualified gas safe registered engineer out,no one will give you any advice on here on how to cure your fault. Sorry mate time to get yournwallet out again!!
  5. B

    Worcester digital timer

    Press the day, hour and minute buttons at the same time to reset the timer. If its still the same then you'll be forking out some cash :D
  6. B

    Boiler Care Plans

    Bg dont sub contract repair work, they get subbies to do the services. One call out a year pays its self and you get your boiler serviced and unlimited callouts. Here we go again with the bg bashing.
  7. B

    Boiler only fires up when plenum chamber cover is removed

    Get british gas out mate, one off fixed price repair and they probably will ADVISE you to change the boiler, but they'll still fix the boiler. Its up to you if you want to change your boiler, only ADVICE.
  8. B

    Boiler noise

    DIVERTOR VALVE. :D
  9. B

    Boiler noise

    Divertor valve methinks. :D
  10. B

    Potterton Suprima 50 firing up, then stopping, then again.

    DON'T PANIC, DON'T PANIC !!!. :D :D :D
  11. B

    Potterton Suprima 50 firing up, then stopping, then again.

    You might want to checkout the diy gas section on this forum.
  12. B

    Potterton Suprima 50 firing up, then stopping, then again.

    I think the gas safe regulations might say different.
  13. B

    Potterton Suprima 50 firing up, then stopping, then again.

    I think your problem might be that your getting plumbers out to fault find on a boiler and unless your qualified then your breaking the law opening up the combustion chamber on your boiler...pay the money ang get someone whos got a clue about boilers, especially yours as its one of the easiest...
  14. B

    Potterton Suprima 50 firing up, then stopping, then again.

    It sounds to me like you should get someone in that knows what they're doing and stop opening up the combustion chamber.(unless your qualified to do so)
  15. B

    worcester 24cdi

    Pump or plate heat exchanger
  16. B

    Worcester greenstar 28i junior - air in pump?

    You are doing gas work if you take the case off that boiler.
  17. B

    Gloworm compact 100e keeps clicking

    Not a cocky answer mate, just saying that if a pcb on a compact needs changed then it has to be done by a registered gas engineer as there are adjustments that need to be made that only a qualified person can do.
  18. B

    Gloworm compact 100e keeps clicking

    It really is a simple job................call out an expert to fix it..........there you go simple wasn't it....... :D 8) :D 8) :D
  19. B

    vokera maxin 24e delayed hot water

    All part off the service.