Search results

  1. Madrab

    Can i get a gas pipe under the drive?

    As suggested, yes they do but as has been exampled, no contractor with any sense will want to take the chance to mole blind if there is any risk of services being near or in line. It could end up costing them and their insurers plenty. The fact that there are 2 chambers directly in the path...
  2. Madrab

    Can i get a gas pipe under the drive?

    There is no way anyone online can really know which it will be. Ultimately the contractor will have to decide when they come on site. That being said, given there are 2 chambers right in line in the drive and without local knowledge of how the services - water - leccy - drainage may actually be...
  3. Madrab

    Hive Single Receiver Wiring Help

    Careful what you are doing with wiring and running lives etc as the boiler may use a volt free contact and if you send 240v down that then you will fry the PCB. Need to test to see what's on that brown and if it actually is 240v Hive works differently, they have a receiver that is wired...
  4. Madrab

    Can I reroute this condensate pipe into the drain?

    All condi pipe is 21.5mm (originally overflow pipe) and it's standard stuff. Just buy the same make of pipe and fittings and solvent weld it, try and avoid Aquaflow from TS.
  5. Madrab

    Can I reroute this condensate pipe into the drain?

    No way that it may be able to be connected to the white waste pipe internally, is it not high enough? Or come through the wall beside the white waste pipe into the gulley?
  6. Madrab

    What sort of tap fitting is this - and how do I tighten it ?

    You'll need one of these on the nut in the middle of that C washer to tighten - https://www.screwfix.com/p/faithfull-monobloc-spanner-set-4-pcs/939rh
  7. Madrab

    Replacing tiled shower floor with shower tray

    OSB3 - and rather than laying full sheets, you could cut lengths the same width as the joists and then just fit them to them, using them as packers to increase the joist height.
  8. Madrab

    Un-demanded heating

    With an S plan there shouldn't be a valve with a white wire! A valve with a white wire is a 3 port mid position valve that is used on a Y plan system. Can you post pics of the valves and their relative position in the system?
  9. Madrab

    Adding an additional rad

    Taking it that there may be a need to use both rads full on, which is the standard approach to design, that 10mm feed will be at its limit providing for the 1400mm rad. The 10mm can be increased to 15mm but it won't take away from the fact that the large rad has maxed out the pipe carrying...
  10. Madrab

    Replacing tiled shower floor with shower tray

    Yes, it's usually easier delivered, there's a lot of weight in 22mm. Any reason for using 22mm, 18mm would be more than enough I would think and they are both T&G, is it just to make up the height? As far as sheds are concerned I believe Wickes used to do it, the larger tiling warehouses should...
  11. Madrab

    Mixer tap spacing

    What type of mixer was there before? 150mm centres on wall mounted bath fillers with a shower diverter has been common for a long time, possibly a European make, given you're in Portugal? No marking, name or anything on it I guess?
  12. Madrab

    Partition devices

    Why would you want to use them? The usual option for safe electrical conductivity in copper pipe would be to bond the pipework. Not sure if these are to function as Dielectric connections in under counter electric water heaters but they are usually used primarily to stop electrolytic corrosion...
  13. Madrab

    Male thread plastic female thread

    Yes - example would be a plastic hose adapter for an outside tap but as suggested it would need a sealing washer as they would normally use parallel threads.
  14. Madrab

    Mixer tap spacing

    Ah ok - so a bath filler as well as a shower diverter? Unfortunately I think you'll be hard pressed. Most, if not all, bath fillers with shower diverter are 150mm here in the UK as they are solid bodied, so the inlets wouldn't move, any adjustment would be through the Z connectors. The only...
  15. Madrab

    Mixer tap spacing

    Most wall mixer taps are, as you suggest, 150mm centres here in the UK. Deck mixers can be different @ 180mm centres and other mixers to utilise the bath holes then need to use upstands to obtain the measurements. Not sure with Portugal though, as with most European country sizes, they all seem...
  16. Madrab

    Rainwater from bathroom gulley coming out of 2 pipes into manhole

    +1, maybe a bit far to travel from Colorado. F.Y.I - This is a UK forum
  17. Madrab

    Bathroom hot water towel rail keeps losing water level

    If the CH is open vent (OV) then there is no real way to monitor the system to see if it's leaking, i.e. if it was sealed then the pressure gauge could be monitored. All that can be done is look for leaks @ valves and any exposed pipe joints. Alternatively if it is OV then put the system on...
  18. Madrab

    Rainwater from bathroom gulley coming out of 2 pipes into manhole

    Time to get back to your insurance then and explain the issue to them, it'll be for them to deal with it. They may send out an independent assessor and get the work checked. As suggested, if they have clearly stated that there should be no connection between the 2 but when water is sent down...
  19. Madrab

    Is a 'water hammer,' always an indication of a problem?

    The type of hammer you are experiencing will be from a loose pipe somewhere. When the fill valve shuts off quickly, it's sending a pressure pulse down the cold pipe and the knock you are hearing is that pulse finding a loose pipe somewhere. Usually on a piece of wood like a joist if it's a low...
  20. Madrab

    ESI 2 Valve to Tado V3 Wireless

    Interesting, looking at the MI, it seems like it may be very specific to those specific stats, given they have 3 matching terminals - +V, 0V, RH The +V and 0V seems to be the 5VDC switching side but not sure what RH would be, maybe something to do with hysteresis for the stats and in effect...
Back