Search results

  1. G

    Boiler Replacement

    yeah that will be plenty for the shower
  2. G

    Boiler Replacement

    ideal logic 30kw will give you about 12.4 litres per minute a 24 will give you 9.9 litres the 35 gives 14.5 litres Hw delivery is your first consideration when going for a combi
  3. G

    Old steel gas pipe removal in 1930's house

    50`s internal pipes would usually have been lead or iron/steel cant think of any houses predating mid 60`s that i have worked in that had copper internals
  4. G

    Boiler Replacement

    LOGIC 35 so a combi so will be sized for HW on a like for like 35 it drops down to 7.5kw the 30 drops to 6.4kw
  5. G

    Boiler Replacement

    replace it for another logic be a doddle of a job as all pipes and flue hole should line up saving you labour costs Get someone local through recommendation from family /friends
  6. G

    Boiler Issues

    edit 1 Position is for lpg o position for NG https://www.freeboilermanuals.com/assets/pdf/viessmann/Vitodens-100-W-Compact.pdf
  7. G

    Boiler Issues

    Sounds like the fast blow fuse in the actual boiler has blown then
  8. G

    Boiler Issues

    righthand button on boiler press it see if that makes any difference check / replace the fuse in the switch besides the clock . 3amp Your clock is in the off position make sure its calling for heat
  9. G

    Gas safety question.

    Do portable gas barbecues get capped off after every use do gas pokers get capped off after every use...eh no because a bayonet is an acceptible method to leave . Whether someone wants to go beyond that is up to them so get it right
  10. G

    Gas safety question.

    Wrong as per usual try reading the regs or even gas safe TBs oh yeah your not qualified so stop trying give advice on something you clearly don't understand... tell you what denso sneek into th CC and see what the pros have said about it somany times in the past..
  11. G

    Can i get a gas pipe under the drive?

    Not too bad in the end then
  12. G

    Can i get a gas pipe under the drive?

    no pics of completed job ? after all the questions
  13. G

    Gas safety question.

    1. That is what purpose made leak detector fluid is for ,only been avialable for half a century at least 2. check them out definetly not AI been on youtube for decades and have spoke to guys i used to work with that have done it . https://www.earthquakewelding.com/live-gas-line-welding...
  14. G

    Gas safety question.

    vide videos on youtube of them being cut and welded live
  15. G

    Gas safety question.

    did i say washing up liquid ?
  16. G

    Gas safety question.

    neither are bubbles
  17. G

    Is this good work?

    looks more like plumbers mate than silicone
  18. G

    Oil to gas install do i need to run the hot water tap?

    as in get out the way while we get on with the job ;)
  19. G

    Gas safety question.

    wrong it is a perfectly acceptable to leave its a basic acs question . Yes a plug is better but do not say no its not
  20. G

    Is this good work?

    would have been quicker to just clean it than take photos and post them
Back
Top