Search results

  1. 333rocky333

    Best plug for 2.5mm flex

    Mk tough plugs use wrap round terminals rather than holes and some people struggle with them, they are good sturdy plugs though
  2. 333rocky333

    Use Maintained emergency light as normal light in garage

    It's too unclear to see what you have actually done with the white wires
  3. 333rocky333

    Is there a minimum size for the cover on an earth rod?

    may be worth looking in regs under labels and identification, some labels have to be certain format, if there is one relevant , then that would denote the minimum size cover
  4. 333rocky333

    Identify these small downlights?

    Maybe just Decklights
  5. 333rocky333

    Does this guy now what he is doing?

    When the spurs are on the end they will form a vertical safe zone, the bottom 700mm or so is likely surface behind units so exempt from being in safe zones
  6. 333rocky333

    Anyone know what this is

    On a ceiling in a restaurant
  7. 333rocky333

    Simplex heater above shop doors

    Some are actually plumbed in with hot water and just have a fan, the smaller electric ones have a total of 3kw internal elements, 3 phase jobbies can be 9kw or more. The theory I believe is as they say it forms a curtain, in reality I think it's a large expense for little reward
  8. 333rocky333

    Brass light fitting adjustment needed

    10mm x 1mm pitch threads are commonly used for lighting so likely unscrews, however cutting and rethreading the square bar may not be easy. Round lighting threaded 10mm bars are available in many options , if that's a suitable option
  9. 333rocky333

    Is the metal back of a GU10 bulb holder live?

    G9 are mains voltage
  10. 333rocky333

    2 way switch issues

    A small plastic connecter chocblock thingy may fit onto that hook thing
  11. 333rocky333

    Motion sensor light that also supplies a load

    Possibly the council hsve now put an led bulb in, if it was a normal bulb before, it may not be designed to work with a led bulb @Andrave2 You should have started a new post really
  12. 333rocky333

    2 way switch issues

    The 2 core red is the supply to the switch that you say is the 1 gang Hall light, just locate that 2 core red at the actual hall light fitting. That's the main wire you need to test, nothing else. This was established ages ago
  13. 333rocky333

    2 way switch issues

    That light is where the supply to the switches comes from, post a pic of that
  14. 333rocky333

    2 way switch issues

    Looks OK, as previously asked does the one way switch (left one with 2 holes in use) do anything on the other 2 gang switch
  15. 333rocky333

    Motion sensor light that also supplies a load

    Surely any bathroom light with a sensor would do, just tap into the wire between the sensor and the driver
  16. 333rocky333

    Twin and earth outside?

    I done a pub swingsign about 30 years ago with 1.5 yellow artic flex on a 10 metre catenery. I still drive past it, the cables now black from London traffic and most hangers have broke or bunched up and the flex is sagging, but still hanging in there, though not sure if the lights still...
  17. 333rocky333

    Lighting didn't come back on

    Often the power to the third room comes from the second room via the round bases mounted on the ceiling, it is quite common for a cable to come adrift if it was loose in the first place, usually after its disturbed
  18. 333rocky333

    Rgb decklights

    Thanks I was a bit concerned putting 12v across the leds as thought may be a bit much. I bought them a few years back and never fitted them till now and when I plugged in the controller it screeches and no lights. It did start to work briefly for a few minute's and I quickly checked It...
  19. 333rocky333

    Obscure Light Switch Wiring

    There's also a possibility there was wall lights at one time, also look for 2 amp sockets at low level sometimes installed for table lamps
Back
Top