  1. S

    Gloworm 40FF Won't power up at all.

    As an update for the boiler someone is coming to sort the thing out the end of the week.:)
  2. S

    Gloworm 40FF Won't power up at all.

    Yes, I'm sure there are a few rogues. There were plenty in both my previous trades. But the burden of responsibility and accountability is still present. I could tell a few frightening stories about some major carriers!
  3. S

    Gloworm 40FF Won't power up at all.

    New board on the way. I'm going to get it fitted to be honest. All signed off then. I know there's some debate about being able to work on them as long as you don't touch the gas. But the way I see it is that it is currently running a PCB that is arranged for it. If I buy another I understand...
  4. S

    Gloworm 40FF Won't power up at all.

    Thank you to everyone for your help. The fault is a broken track after the live (black) pin to the fuse. One of the pcb pins for the multifunction control fell apart when it was unplugged as well. I have managed to salvage the pin and have soldered a jumper cable in for the track. A new...
  5. S

    Gloworm 40FF Won't power up at all.

    Thanks for the replies.:) The exact model is a glow worm Micron 40ff. I have just checked the resistance of the thermistor and that is 17kohms. The resistance of the connections ( thermistor) on the board was 3M ohms. On removing the board I found some blackening that appears old and a...
  6. S

    Gloworm 40FF Won't power up at all.

    Hello, I wonder if someone could give me some advice? We have a Gloworm 40FF. It's around 11 years old and had a service a couple of years ago. About two weeks back the radiators started coming on with the hot water. We have lived with that whilst we try to get some cash to sort it out (...