  1. andyr123

    16amps on a 13a socket

    Is the 2.5mm wiring behind the double 13a socket OK for it? - I see 2.5mm is good for 24amp single phase but does that double to 48amp on a ring circuit? - if you plugged in 2x 3kw appliances that would amount to 25amps wouldn't it? so even if the socket would withstand it what effect would that...
  2. andyr123

    16amps on a 13a socket

    if you plugged in 2 plugs of heavy appliances of 2kw each (say a tumble dryer on full heat, and a 2kw Fan heater) into a double socket wall outlet 2x2kw @240vac = over 16amps - yet a 13amp twin socket outlet is designed to plug in 2x 13a plugs , how is that? there would be a tremendous amount of...
  3. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    Yep our boiler, PRV fitted and no valve between F&E pipe and CH pump on the return and vent pipe lagged and goes over top of header tank and AAV fitted on flow of coil pipe of immersion cylinder
  4. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    I'd be concerned on a system without a seperate vent pipe hanging over top of F&E header tank that someone had put a gate valve on the feed (that acts as expansion) that if they closed the valve there would be no where for air water to escape should boiler overheat
  5. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    a lot of AAV's these days come with a valve underneath so when you unscrew/remove the bottle part of the AAV the water shuts off so you can replace the AAV if it packs up and needs replacing, as the thread of the AAV screws back on it just automatically opens up the washer
  6. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    fascinating that though because if you have got a system where you have a bent over pipe over the top of the feed tank its end is always open , not covered by water so as water heats up it expands and also pushes air out through the hole , so the air would escape through that way , just same as...
  7. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    I see what you mean - my kerosene oil boiler setup has a couple of overheat features, a pressure relief valve in the boilers flow pipe (its an outdoor boiler unit) that opens when water gets around 90'c - then also an electrical cut out in the burner thermostat switch for if it overheats (or...
  8. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    nah, that dont sound right at all then to me - I would branch off your pipe at the bottom of the tank to another pipe going above your F&E tank and bent over the top to make a proper combined F&E system then ... plus also safer if boiler should ever overheat, the water then will just boil up the...
  9. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    this is how I understand feed and vent (this is not combined F&E) to work , it acts as one way valve so it wont suck air in through the vent pipe - but it will expand when it needs to and release into tank if boiler overheats:
  10. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    are your copper pipes going to your boiler 22mm or 28mm ? - fully pumped or gravity or gravity/pumped?
  11. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    Odd , not seen that combined F&E before done that way - the only combined F&E I have seen is the pic I posted above , where the vent pipe hangs over the top of the header tank And older systems fed and vented like this:
  12. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    is the F&E vent pipe going over the header tank in the loft on your system like this?
  13. andyr123

    Strange air noise and “whooshing” near pump in an otherwise efficient central heating system

    hi - have you got an AAV anywhere in the system pipework at all? - if you have you can try opening up black/red plastic cap and see if any air releases?
  14. andyr123

    Kerosene oil boiler cycling on and off - not starting fully

    yes thats the strange thing - the only smoke come out of the flue is the white condensation and its not smelly unburt kersosene smell (when its working right - when its not starting right like today it was smelling then) but yeah the inside of the flue is black and sooty so yeah it most probably...
  15. andyr123

    Kerosene oil boiler cycling on and off - not starting fully

    yes your most probably correct , there is even a filter behind the jet on this burner . im just gonna keep an eye on it. A new jet wont break the bank but a analyzer would . In that case I will get someone to come out and do it
  16. andyr123

    Kerosene oil boiler cycling on and off - not starting fully

    Sorted within minutes of posting this I went out, took off blast tube and cleaned electrodes and jet and its firing up now and staying fired up - hopefully fingers crossed that is all it was , I am just keeping an eye on it.
  17. andyr123

    Kerosene oil boiler cycling on and off - not starting fully

    hi all. Our Grant condenser boiler with a RDB2.2 Burner is not firing up properly. its stopping and starting in a loop, terrible smell of unburnt kerosene in the air. Things I have tried today so far. Cleaned Photocell with cotton bud - Photocell and black rubber shaft has load of black soot on...
  18. andyr123

    Hoover Tumble Dryer - Drum not moving... sometimes

    Hi all - I have this old Hoover One Touch Tumble Dryer . 9 times out of 10 the drum will revolve (and both ways fine without intervention and when it does, it dries the clothes normally , but every now and again I am in the other room and can tell the drum has stopped moving around. I go...
  19. andyr123

    Just cannot get rid of this injection fault on clio mk4 diesel

    Its strange that its a MAP (pressure) sensor as well if it is, because it has a Temp sensor thing in it, and there is already a MAP there on the top of the engine - this one: