Search results

  1. S

    Slope of bath waste into soil stack too steep?

    I think it's about the water flowing quicker than the solids which get left behind (presumably hair) and possibly sucking out the water in the traps. Ah okay. I'd thought the maximum you could get away with was 90mm per metre. (The first couple of metres in the bathroom has the correct...
  2. S

    Slope of bath waste into soil stack too steep?

    Hello I'm adding a 50mm waste from a bath/basin into a soil stack, which already has two separate shower wastes connected. The only available position for a boss strap would mean a 19cm drop over a 107cm run. I can see the regs say this is too steep, but adding a vertical drop to get a...
  3. S

    Do basin fixing kits work?

    Thanks, I’d prefer them over screws. If the basin ever needed to come off the bolts could stay (assuming the distance between the holes is standard!)
  4. S

    Do basin fixing kits work?

    I don’t know. Maybe a coach screw/washer? Is it that straightforward? On the screw threads or on the ceramic? Thanks fo replying.
  5. S

    Do basin fixing kits work?

    Hello. I have a wall hung basin for an en suite and have bought a Rawlplug fixing kit (140mm x 10mm bolt). It’ll be going through tile, tile backerboard and into timber. I would have got the Fischer kit but it had a couple of negative reviews. I don’t plan to sit on it but do these kits...
  6. S

    Do you include the vertical run when deciding waste pipe diameter size?

    Thank you, that will reduce some of the hassle!
  7. S

    Do you include the vertical run when deciding waste pipe diameter size?

    Thanks, I’ll put an anti siphon trap on the bathroom basin. Back to the shower room and the long run. For peace of mind I’ll replace the 40 with 50. Could the first horizontal run and elbow into the vertical stay as 40? I don’t know if you can see from this photo but the vertical pipe...
  8. S

    Do you include the vertical run when deciding waste pipe diameter size?

    Okay thanks. I'll give it a go. So now I'm wondering about the bath waste (different room). It runs horizontally for a metre to a swept tee where the basin joins. Then another 1.5m through the outside wall with a 30cm turn to the soil stack. Seeing as it's a bath should that be 50mm too?
  9. S

    Do you include the vertical run when deciding waste pipe diameter size?

    If I put a small handbasin nearby could I put an anti syphon trap on that?
  10. S

    Do you include the vertical run when deciding waste pipe diameter size?

    Okay thanks for the replies, much appreciated
  11. S

    Do you include the vertical run when deciding waste pipe diameter size?

    Thanks. It’s not connected at the shower end. So I’m going down a rabbit hole to try to understand this! I’m reading that on vertical drops water will flow in a vortex (so long as it’s vented), which lets air in and stops the suction effect. Does the open end of the soil stack mean that it’s...
  12. S

    Do you include the vertical run when deciding waste pipe diameter size?

    Thanks - would you mind describing what the issue might be. I'm reading about laminar and turbulent flow but don't really understand it. Is it about sucking the water out of the trap? Would it help if the last horizontal run (on the outside) was 50 but the vertical remained at 40? Thanks
  13. S

    Do you include the vertical run when deciding waste pipe diameter size?

    Hello I’m wondering if I’ve made a mistake here. I’ve got a 40mm shower waste outlet which runs less than a metre horizontally before it drops vertically for 2.5m, then goes outside for a further 2m horizontal run to the soil stack. I see regs say anything over 3m should be 50mm but does that...
  14. S

    Joining 1.5mm cable to 2.5mm?

    Ah, superbly explained, thank you. So something like this, plus box https://www.tlc-direct.co.uk/Products/WKSG20SE.html As I understand it, only required at one end because the inner earth will be used?
  15. S

    Joining 1.5mm cable to 2.5mm?

    Thanks. I’m beginning to think it’s a job for the electrician as I’m not clear on how I would deal with earthing the armour. One end would terminate in an FCU on the T&G ceiling of the shed (the previous owner called it a summerhouse), the other end would join to a junction box inside under...
  16. S

    Joining 1.5mm cable to 2.5mm?

    As far as I know the original cable came direct from the CU, would that make a difference? How much difference does it make having the FCU in the house rather than in the shed? If you wanted to isolate or work on any of the sockets or switches you would just switch off the FCU. Anything...
  17. S

    Joining 1.5mm cable to 2.5mm?

    Thanks for the replies. The load will be three low voltage lights plus the socket in the garage. It doesn't have anything plugged in there permanently, a pressure washer is the the heaviest load that might get plugged in. If that's too much, it could just as easily run from the house. So is...
  18. S

    Joining 1.5mm cable to 2.5mm?

    Run from the house 3m. From shed to garage and an outside light another 4m. Electrician was fine with me running the cable, there’s a lot going on and he comes in when things become certifiable. 1.5 mm was deemed okay because, if I recall correctly, it had a higher capacity that would...
  19. S

    Joining 1.5mm cable to 2.5mm?

    So in tacking the job in my other post, I’m wondering if I could potentially solve another problem. The garden shed, garage and outdoor light no longer work and the faulty cable was taken out of the CU. New 1.5mm armoured cable has already been run from the shed to the house but to get it to...
  20. S

    Cable and insulation

    Thanks. I could also try to enclose it in plastic trunking but it’d be a lot easier to just lay plasterboard over it.