  1. Risteard

    KITCHEN SOCKETS tripping RCD

    In fairness I would suggest that it's very common for socket-outlets nowadays to be DP switching, although it was certainly much less common in the past.
  2. Risteard

    80A PME Fuse

    If you can afford to pull more than 60A constantly through the night then you should probably just rapid charge your EV rather than fit a chargepoint, and heat your house by burning banknotes in an open fire.
  3. Risteard

    80A PME Fuse

    Absolutely no need. Even a 60A supply would be more than ample. In fact you need advance permission from the DNO to exceed 60A/phase with an EVSE.
  4. Risteard

    Using a double pole swich for outside light

    Given the illegality of it under ESQCR any claim of it being "safe" would seem somewhat foolish.
  5. Risteard

    Using a double pole swich for outside light

    Would it indeed? Would the courts concur?
  6. Risteard

    Using a double pole swich for outside light

    "Not unsafe" is merely an opinion.
  7. Risteard

    Aico alarm wiring instructions

    Yes it does, and as per @SimonH2's response.
  8. Risteard

    Aico alarm wiring instructions

    You were the one who asked what was used there though. And by all means look it up.
  9. Risteard

    Aico alarm wiring instructions

    RD415 cable is used in the south of Ireland for domestic smoke/CO detector installations. It has a pink sheath. And, contrary to your beliefs, it is absolutely used for smoke alarm installations despite not being used for other purposes.
  10. Risteard

    wiring up a lighting photocell without a neutral wire?

    An oldish thread, but here's an example: https://www.boards.ie/discussion/2058108505/andy-from-sligo?utm_source=community-search&utm_medium=organic-search&utm_term=andy+from+sligo
  11. Risteard

    wiring up a lighting photocell without a neutral wire?

    Are you ever on boards.ie now? I see you are missed by many there when you're not on. You're a national treasure at this stage.
  12. Risteard

    wiring up a lighting photocell without a neutral wire?

    A Registered Electrical Contractor (REC) could sort this for you Andy from Sligo.
  13. Risteard

    EV Charger, earth connection to pipework

    Main protective bonding (equipotential bonding) is completely different to Earthing, and is a fundamental safety requirement.
  14. Risteard

    Are these C2s or C3s

    Hager may not be the best option for that, as their single module RCBOs do not break the neutral, which is a requirement for a circuit supplying an EVSE.
  15. Risteard

    Plug Top 13A Fuse

    It's known as Mode 2. "Level 1" is an American term.
  16. Risteard

    Armoured cable sizing

    You don't get SWA glands at any of the sizes you mentioned. Are you sure you know what you are doing?
  17. Risteard

    Economy 7 meter

    It's possible I suppose, but I just don't know. Our definitely just keeps time rather than syncing so far as I can tell. My immersion heater, chargepoint and electric van all have the offset from correct time so as not to use extortionate peak electricity consumption!
  18. Risteard

    Economy 7 meter

    My (digital) one is approximately two minutes and three seconds out. Can't say whether it's by accident or design.
  19. Risteard

    Economy 7 meter

    Interestingly here every Economy 7 tariff (regardless of supplier) is 1a.m. to 8a.m. GMT (i.e. 2a.m. to 9a.m. during daylight savings).
  20. Risteard

    Comando Socket for EV charging (In Scotland)

    And for completeness DC rapid charging (CCS/CHAdeMO) is Mode 4.