  1. chivers67

    Cable pulling

    You could try to see if a fish tape could push through and attach some strong blue rope if it does to use as a draw rope. Definitely do what ^ Murdochat ^ above suggests in the first instance
  2. chivers67

    what size cable - Garden consumer unit

    Run a Screened Cat6 with it use a hosepipe or duct to protect it. I ran 10mm to my Garden room for sockets the Electrician you hire will probably do the same or 16mm, really depends on the power consumption the Sauna will require.
  3. chivers67

    Socket fault

    I didn't say there were than five EFL, just that one is held in by the screw holding the back box in on the right above the live brown cables - which isn't normal.
  4. chivers67

    Socket fault

    I'm not sure why one of the earths is held by a screw against the back box on the right, maybe whoever did this did it due to it not reaching the socket. It's not normal to have four cables connected in a socket but two might just be spurs to other sockets & the other two part of a ring or...
  5. chivers67

    fitting a double gang socket to a desk back panel

    So if I'm reading this correctly you can install a normal back box that's 25mm deep (33mm) or chase out some plaster to use a deeper 35mm box? Bury it as long as it's in an obvious safe zone place it in metal conduit if it's not so it's mechanically protected, surface mounted trunking will look...
  6. chivers67

    Switching from 4 bulb flush light to single pendant: too many wires?

    Looks like you have two switches in the kitchen, a feed in and a feed to the next lot of lights. Have you a volt stick to see which is the incoming feed (probably the "blue wire")?
  7. chivers67

    Installing a wall light

    Can you send a photo of the Switch wiring? You'll need a minimum of a T&E feeding your wall light from the switch
  8. chivers67

    Confused by new kitchen lights

    The Way that's been terminated looks a little poor, the Brown has too much copper on show, is that black terminated into the switch got damaged insulation? I don't know why the grey outer sheath hasn't been stripped back more so there's more room in the back box.
  9. chivers67

    Juntion Box in Airing Cupboard

    It will be accessible so something like this > https://www.tlc-direct.co.uk/Products/CHOC30A.html As you'll have stranded and solid core
  10. chivers67

    Installing wall lights

    The lights don't look heavy though and the hook is secured well to the wall.
  11. chivers67

    Installing wall lights

    I would just plaster over the conduit & junction box and leave the "slit" so the wires are still accessible and it's hidden by the wall light. Looks a bit of a bodge but a good bodge & the fitting is earthed.
  12. chivers67

    RCD TRIPPING after hoover gets plugged in

    Yes I looked at all circuits with Limitation on all IR testing, one could at least lower to 250v and do some kind of test on some circuits. With regards to the sockets they should be able to be switched off and End to end resistances have been taken so not sure why no IR.
  13. chivers67

    Which of these sockets are in the right place? (If any)

    Could be a right pain in the arse to move it depending on how the cable comes up, might not reach without replacing one part of the ring - if it is a ring.
  14. chivers67

    Bathroom pull switch

    Maybe Quinetic could be the answer https://www.tlc-direct.co.uk/Main_Index/Quinetic/index.html
  15. chivers67

    Extending loft light

    Get an LED Baton and as Pete says extend off the existing light it's an easy enough job. One thing I'd also do is staple some Silver Radiator Heat reflector foil near the top of the Rafters as this reflects light where you want it..
  16. chivers67

    EICR and fuse box

    Not much a few things but I'm surprised you got an Electrician willing to "Pass" that in 2020. It's a flat by the looks of the title of the JPEG and the fact it only has 4 circuits. They're not labelled for starters the fuse cover is missing which should have those details but sockets should...
  17. chivers67

    EICR and fuse box

    No, is there an RCD unit that protects the installation anywhere?
  18. chivers67

    Cooker hood - hole in ceiling but no duct

    Yes speak to your neighbours and see if they actually have a vented extractor, you'd expect that in new builds these days! You might be able to see if other houses have vents.
  19. chivers67

    Cooker hood - hole in ceiling but no duct

    Can you get some plaster board or plywood and cut a hole in it the size of the hole that's there? Place a piece of wooden batten across the inside with a few inches either side of the hole bridging it and fix this with a screw each side and then screw the circular piece of plaster board/plywood...
  20. chivers67

    Circuit board query

    How did you work that out? A damp cloth was used to clean the fan.