  1. 333rocky333

    Mains indicator LEDs

    Ok Message me and will sort something
  2. 333rocky333

    LED Floodlight Q

    Most would mount a squarish box adjacent, I prefer plain sided boxes and drill own holes, though most use 3 x 3 threaded wiska 306 boxes but I think there ugly with all the unused outlets. There's also a smaller 206 box Often you can visibly loose them behind the fitting. Both boxes have...
  3. 333rocky333

    Mains indicator LEDs

    Hi @JohnD I now have a small stash of at least ten of these now, if you still want them let me know
  4. 333rocky333

    replacement neon (or LED) indicators

    @npaisnel There's a more up to date post on this Thread 'Mains indicator LEDs' https://www.diynot.com/diy/threads/mains-indicator-leds.633281/
  5. 333rocky333

    Wall mounted spotlight with room for cables!

    @theflyingpig From your initial post, it appears you intended to push the join back within the wall. How would that conform. @trojanhawrs I suggested terminating it within the base of the enclosure, which is the way a vast majority of wall mounted fittings are mounted. The fitting becomes the...
  6. 333rocky333

    Wall mounted spotlight with room for cables!

    It appears ample room if you strip the grey and the white sheathing more
  7. 333rocky333

    Wattage on the Rear of Light Switches

    Plate switches always have current ratings and are rated at 6a or 10a and sometimes 20a, ideally they should be rated to the mcb size, but as most domestic lighting circuits are 6 amp then by default any switch is suitable. In past days you derated a switch for certain types of load, but...
  8. 333rocky333

    95x95 light switchs

    Most dimmer modules are removable, so even if you got a 85 x 85 one the module could likely be undone and refitted to your existing front plate. Bare in mind what lamps your dimming as that affects the rating you need. Your old dimmer has minimum load of 60 watt, if you are dimming less or...
  9. 333rocky333

    Make of grid/switch/dimmer modules?

    Apparently screwix do varilight and the metal grid looks the same, yours is actually upside down
  10. 333rocky333

    Make of grid/switch/dimmer modules?

    Don't think varilight make actual grid switches, the white adapters are for different makes of grid, to allow fitting there own varilight dimmer, you would need to establish what make grid the second ones actually for.
  11. 333rocky333

    95x95 light switchs

    Switches with an edge pattern are usually larger, this is so the pattern is continues around the edge without the fixing screws intruding the pattern. It was more common with metal switches with a roped edge that became popular in the 80's
  12. 333rocky333

    Make of grid/switch/dimmer modules?

    Crabtree ones screw in and mk are more rounded so it's not them. What's the code on the metal grid, that could help, failing that look at pics of a varilight dimmer as it shows 7 popular profiles one may match yours and lead to the make.
  13. 333rocky333

    Best plug for 2.5mm flex

    If there long ferrules suppose you can wrap them round a bit According to regs though , ferrules are only needed for certain types of terminals, assuming this don't Include the ring terminal, is there any reason not to cut them off.
  14. 333rocky333

    Use Maintained emergency light as normal light in garage

    One is the inverter and ones the ballast, they work together, In Normal mode the ballast runs both tubes from its own switched supply. However the 240 v switched supply to the ballast first goes via N/C contacts on the inverter, that open on loss of the permanent feed at the inverter...
  15. 333rocky333

    Use Maintained emergency light as normal light in garage

    What's different? The main thing to ensure is 1 2 and 3 are connected to the same tube and 4 5 and 6 to the other tube
  16. 333rocky333

    Best plug for 2.5mm flex

    Mk tough plugs use wrap round terminals rather than holes and some people struggle with them, they are good sturdy plugs though
  17. 333rocky333

    Use Maintained emergency light as normal light in garage

    It's too unclear to see what you have actually done with the white wires
  18. 333rocky333

    Is there a minimum size for the cover on an earth rod?

    may be worth looking in regs under labels and identification, some labels have to be certain format, if there is one relevant , then that would denote the minimum size cover
  19. 333rocky333

    Identify these small downlights?

    Maybe just Decklights