    Anyone measured how much gas or oil used to heat DHW with the central heating?

    . How long do you think pay back would be for buying and having an undersink heater
  2. G

    Can i get a gas pipe under the drive?

    Cant see them moling that they will more than likely dig this
  3. G

    Baxi 105e: Leak after replacing plate-to-plate heat exchanger

    The seals are a wee bit awkward to get out a bent pick is handy for them out of the countless plates on 105`s i have had in and out i have only ever had one original seal leak so you are a wee bit unlucky You could try a bit of silicone grease onto the existing seals see if that works
  4. G

    Q for the plumbers - not paying you due to wishy washy invoice?

    Yep not unreasonable to ask what the actual repair was and what has been changed etc
  5. G

    Radiators : Toolstation / Screwfix

    Have a look at wickes they are made by stelrad and a better rad
  6. G

    22mm / 3/4" straight through wall plate flange

    Dont make them because there is no demand for them . Here is an elbow type . if you dont want to go with madrab idea https://www.bes.co.uk/pipe-tube-fittings/pipe-fittings/compression/compression-wallplate-elbow-22mm-x-3-4in-17717/
  7. G

    Sentinel inhibitor

    No it wont clear sludge you need x400 first then once flushed you add x100 . X200 is a silencer and will quieten noisy boilers
  8. G

    Baxi 105e

    on both then initially change the main sensor in the dry pocket
  9. G

    Magnetic filter.

    DO NOT TOUCH the isolating valves unless you want a very high chance of them leaking Plenty of room ? there is about 6 inches of pipe on show
  10. G

    Baxi 105he pump pulsing on/off

    yeah venturis fall apart usually show up first on thermostatic showers , Tip to get all the bits out tape a bit of hose pipe to your hoover hose and quick switch on gets all the bits out
  11. G

    Baxi 105he pump pulsing on/off

    only ever had the lead to a 105 gas valve faulty once and that was about 20 years ago there is diodes in it seemingly , yep a strange one
  12. G

    Essex flange, ect

    what temp is your cylinder stat set to because if its too high cavitation can occur in the shower pump So keep it below 60 degrees
  13. G

    Baxi 105he pump pulsing on/off

    Worth checking for a neutral fault to
  14. G

    Baxi 105he pump pulsing on/off

    certainly a head scratcher
  15. G

    Baxi 105he pump pulsing on/off

    long shot Have a look at the condense trap there is two wires on top of it pull the one at front off see if it fires up .
  16. G

    Magnetic filter.

    i wouldnt bother then
  17. G

    Baxi 105he pump pulsing on/off

    very strange fault Was it a brand new pcb or reconditioned and definitely not an instant pcb by mistake . Earth wires from and to pcb re connected /altered Correct wires put back on sensors / red to ch sensor green to hw sensor Has anything else been done to boiler ? Polarity well worth a check
  18. G

    Magnetic filter.

    Do all your rads heat up with no cold spots
  19. G

    Baxi 105he pump pulsing on/off

    when you say nothing happens when hot water runs . do you mean no demand light comes on and it doesnt fire ? Does the pin come out and hit the microswitch
  20. G

    Baxi 105he pump pulsing on/off

    105 instant ?