    Doorbell transformer query

    I don't know but on a related tangent, I think efficiency drivers also contribute to the lack of robustness in a lot of things, not necessarily just the fact it's cheap materials or poorly made. Pumps for instance pack more of a punch in a smaller format than they used to, but even with full...
  2. T

    Doorbell transformer query

    I'm with you, its a piece of history probably hand wound by somebody's grandad! Nice to think it's still buzzing along nicely all these years later.
  3. T

    EV charger installation possible?

    The fuse carrier might say 100A, but without removing it you can't be certain what the actual fuse size is - it's common practice for smaller fuses to be fitted. You may be able to find this out from the DNO, if they don't know then most electricians wouldn't have qualms about checking it. Looks...
  4. T

    EV charger installation possible?

    @ericmark I know what you're saying, I don't think that's the case though. The design load of the entire installation can be taken into consideration rather than speculating that every single circuit is simultaneously being used to the brink of overload - otherwise the right hand RCD would be...
  5. T

    High pitched whine that rises and falls for hours after central heating has been on

    I would say you shouldn't have any AAVs fitted to an open vented system full stop. In an unvented system it wouldn't matter if it was on the return.
  6. T

    EV charger installation possible?

    Are you saying diversity isn't taken into account for that? If so that's news to me, and I wouldn't be surprised if other electricians have fallen foul of it (I would like some proof though).
  7. T

    EV charger installation possible?

    The RCD type units supplied in most (all?) EV chargers aren't compliant with the british standards because they're not a mechanical switch with a test button. So basically, you do have to have a RCBO but there's no reason you couldn't have one fitted to that CU (I'm not sure whether lewden make...
  8. T

    Comando Socket for EV charging (In Scotland)

    As you alluded to in your previous post the chance of a PEN fault is pretty remote - the reason it's mandated for car chargers is that in the event of a fault the chance of coming into contact with energised metalwork is extremely high, this isn't necessarily the case for a lot of portable tools...
  9. T

    Comando Socket for EV charging (In Scotland)

    Can't see it saving you any money at all, you can pick up one of the Screwfix tethered chargers for £350, and that's only a single unit to install. I don't see a massive issue with your idea, technically chargers are supposed to be supplied with a "dedicated" circuit but you could argue it would...
  10. T

    Should be simple? change inline smart switch

    You can get them for about a quid in Screwfix, but yes.
  11. T

    Should be simple? change inline smart switch

    The fused spur is already there, I'm just proposing you change the back of it for a slightly deeper one
  12. T

    Replace dial thermostat with portable one.

    You'd be better off replacing your programmer rather than your thermostat for a dual channel receiver. Then you can control the hot water and heating through the wireless thermostat.
  13. T

    Outside socket and light options

    Lol you're dreaming, once it's in it'll be staying like that till the end of time! If using pvc conduit you use these and swap the bush for a m20 stuffing gland. Cut a short nipple of conduit to join. Or you can use a junction box if you prefer.
  14. T

    Outside socket and light options

    A couple suggestions/questions. Does your ring circuit currently have RCD protection? If not, you'll need to fit a RCD socket for outside. Does the light need to be switched? A lot of outside lights have PIR (motion) sensors and dusk to dawn settings. If you're running the cable externally...
  15. T

    Should be simple? change inline smart switch

    Having it looking like it's precariously balanced on the edge of the fused spur wouldn't be my definition of neat. I don't think the fused spur box will be big enough as it is, if you buy this and replace the back box I think it'll fit though. Are those wires coming out of the spur or out of...
  16. T

    Radiator diagrams - where can 22mm change to 15mm?

    If your existing pipes are run in notches under the floorboards, cutting out and replacing with copper is the best solution. Rodents can't chew copper!
  17. T

    Pressure tester to UFH manifold adapter

    Probably something like this
  18. T

    Thermostat installation help

    I don't think it's a workable solution, which is why I suggested running a new cable. If that's unfeasible, my next suggestion would be to buy a wireless thermostat instead, and mount the receiver next to your "wiring centre", again with a new cable - edit : actually in this case you'd likely be...
  19. T

    Thermostat installation help

    Left bottom cable to boiler, right bottom to thermostat correct? Would you be able to run a new thermostat cable easily enough? Extending it on both sides is going to be crap. I'd go for a 1mm 4-core flex.
  20. T

    Thermostat installation help

    Where is the white cable on the top of that picture going?