  1. dilalio

    Under Floor Heating Temperature

    Look up priority hot water with your boiler. It would need some pipework and component changes. Not exactly sure without research but it may allow you to have temp for DHW different to that for CH... your boiler may or may not support this... You could also look into CCTs (close coupled tees)...
  2. dilalio

    Under Floor Heating Temperature

    You could make the system priority hot water and then set the CH flow temp to suit the UFH and rads.
  3. dilalio

    What trap, washing machine and dryer

    Don't know if the spigots come with something that will take the condensate hose from the dryer... You'll have to make it fit if it doesn't.
  4. dilalio

    Pan Connector not central

    Could me marmite for all I know ;) Taste it maybe :) Twist and pull and maybe some washing up liquid to help push n pull.
  5. dilalio

    Under Floor Heating Temperature

    Well, if all but the smallest zones are off, and the mixing valve works as it should during open zone demand, then the mixing valve may, as wunda have said, become overwhelmed! The boiler pump should also modulate to decrease the flow rate and not over stress the mixer. Do you have any...
  6. dilalio

    Under Floor Heating Temperature

    OK, so, just to confirm... The only loop with issues is the hallway one, when all other circuits are satisfied?
  7. dilalio

    Under Floor Heating Temperature

    OK but is the flow pipe going into the correct port on the blending valve? 55° is not out of the park for UFH flow temp. What is the target floor temp for your LVT? What can it withstand? How and where are you measuring temperatures?
  8. dilalio

    Under Floor Heating Temperature

    It's not a valve. It's the fan speed and burner which "modulate" - basically like your foot up and down on a car accelerator pedal, or turning a gas hob dial up and down.
  9. dilalio

    Under Floor Heating Temperature

    What's the GC number of your greenstar? If it's a modern one, it should have a turndown ratio of 10:1, meaning that it can modulate down to 10% of its maximum output so - 30kW to 3kW. If your ufh heatloss is lower than this, the boiler will cycle on and off. But! The blending valve should...
  10. dilalio

    Under Floor Heating Temperature

    Is flow and return the correct way round, going into the blending valve?
  11. dilalio

    Under Floor Heating Temperature

    What is this? Not sure what you're referring to here!
  12. dilalio

    What's this press fitting brand?

    Thanks to all repliers. Backflushing worked and I got this out of the MLCP...
  13. dilalio

    New Boiler issues..

    Boiler slingers?
  14. dilalio

    WC Connector Boss Vent

    I've always known the connection to be for a vent and the description on your link concurs. I have also used them to connect other drains though... Basin, condense etc.
  15. dilalio

    Filling loop passing slightly?

    When you replace it, make sure you put the NRV part of the loop on the mains feed... Forget the way it comes made up. Then it's easier to drain in future.
  16. dilalio

    New Boiler issues..

    How many rads? How old is the system? Is it 15mm throughout even right near to boiler?
  17. dilalio

    New Boiler issues..

    How have they filled in the benchmark commissioning page? What did they put where it asks about radiators/system being properly balanced?
  18. dilalio

    Worcester-Bosch Greenstar 24i Junior - Hot Water Not Very Hot

    Incoming Flow rate and delta T of boiler first (usually 35° rise from cold main temp). Then measure flow rate at a hot tap. If it's not performing as per MI's then look for crossover.